Importance of measuring the time course of flow-mediated dilatation in humans

被引:316
作者
Black, Mark A. [1 ,3 ]
Cable, N. Timothy [1 ,3 ]
Thijssen, Dick H. J. [1 ,3 ]
Green, Daniel J. [1 ,2 ,3 ]
机构
[1] Liverpool John Moores Univ, Res Inst Sport & Exercise Sci, Liverpool L3 2ET, Merseyside, England
[2] Radboud Univ Nijmegen, Med Ctr, Nijmegen, Netherlands
[3] Univ Western Australia, Crawley, WA, Australia
关键词
blood flow; arterial diameter; high-resolution ultrasound; doppler; shear rate;
D O I
10.1161/HYPERTENSIONAHA.107.101014
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Flow-mediated dialation ( FMD) is widely used to describe conduit artery endothelial function. The traditional approaches to FMD calculation assess diameter change at arbitrary time points after occluding cuff deflation. The aim of this study was to examine the time course of brachial artery FMD after a 5-minute period of forearm ischemia in 12 young, 12 fitness matched older and 12 older untrained subjects. Edge-detection and wall tracking of high resolution B-mode arterial ultrasound images, combined with synchronized Doppler waveform envelope analysis, were used to calculate brachial artery diameter, blood flow, and shear rate continuously across the cardiac cycle after forearm ischemia. FMD was significantly higher in young healthy subjects ( 7.8 +/- 3.2%) compared with sedentary older subjects ( 5.2 +/- 2.8%, P < 0.05) but not trained older subjects ( 6.4 +/- 2.3%). Time to peak diameter differed between young ( 50 +/- 11 seconds) and both older groups ( trained; 80 +/- 21, P < 0.001; sedentary: 83 +/- 36 seconds, P < 0.001). A large proportion ( > 42%) of true peak diameters fell outside the time frames typically used to assess FMD in the literature. When calculated according to the commonly used approach, ie, 60 secs after cuff deflation, FMD was significantly lower compared with true peak FMD in all groups ( P < 0.001), and no differences were evident between the groups. The time course of FMD differs significantly between young and older subjects. Studies assuming that peak dilation occurs at an arbitrary time point, or within limited time windows, may draw misleading conclusions regarding differences between groups. More sophisticated approaches to measurement of FMD are required if it is to be considered a valid biomarker of vascular disease.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 33 条
  • [1] NONINVASIVE DETECTION OF ENDOTHELIAL DYSFUNCTION IN CHILDREN AND ADULTS AT RISK OF ATHEROSCLEROSIS
    CELERMAJER, DS
    SORENSEN, KE
    GOOCH, VM
    SPIEGELHALTER, DJ
    MILLER, OI
    SULLIVAN, ID
    LLOYD, JK
    DEANFIELD, JE
    [J]. LANCET, 1992, 340 (8828) : 1111 - 1115
  • [2] IMPAIRED ENDOTHELIAL FUNCTION OCCURS IN THE SYSTEMIC ARTERIES OF CHILDREN WITH HOMOZYGOUS HOMOCYSTINURIA BUT NOT IN THEIR HETEROZYGOUS PARENTS
    CELERMAJER, DS
    SORENSEN, K
    RYALLS, M
    ROBINSON, J
    THOMAS, O
    LEONARD, JV
    DEANFIELD, JE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (03) : 854 - 858
  • [3] Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery - A report of the International Brachial Artery Reactivity Task Force
    Corretti, MC
    Anderson, TJ
    Benjamin, EJ
    Celermajer, D
    Charbonneau, F
    Creager, MA
    Deanfield, J
    Drexler, H
    Gerhard-Herman, M
    Herrington, D
    Vallance, P
    Vita, J
    Vogel, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (02) : 257 - 265
  • [4] Endothelial function and dysfunction. Part I: Methodological issues for assessment in the different vascular beds: A statement by the Working Group on Endothelin and Endothelial Factors of the European Society of Hypertension
    Deanfield, J
    Donald, A
    Ferri, C
    Giannattasio, C
    Halcox, J
    Halligan, S
    Lerman, A
    Mancia, G
    Oliver, JJ
    Pessina, AC
    Rizzoni, D
    Rossi, GP
    Salvetti, A
    Schiffrin, EL
    Taddei, S
    Webb, DJ
    [J]. JOURNAL OF HYPERTENSION, 2005, 23 (01) : 7 - 17
  • [5] Xanthine oxidase does not contribute to impaired peripheral conduit artery endothelium-dependent dilatation with ageing
    Eskurza, I
    Kahn, ZD
    Seals, DR
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2006, 571 (03): : 661 - 668
  • [6] Low-density lipoprotein subfractions and cardiovascular risk in hypertension - Relationship to endothelial dysfunction and effects of treatment
    Felmeden, DC
    Spencer, CGC
    Blann, AD
    Beevers, DG
    Lip, GYH
    [J]. HYPERTENSION, 2003, 41 (03) : 528 - 533
  • [7] Effects of race and hypertension on flow-mediated and nitroglycerin-mediated dilation of the brachial artery
    Gokce, N
    Holbrook, M
    Duffy, SJ
    Demissie, S
    Cupples, LA
    Biegelsen, E
    Keaney, JF
    Loscalzo, J
    Vita, JA
    [J]. HYPERTENSION, 2001, 38 (06) : 1349 - 1354
  • [8] Assessment of brachial artery blood flow across the cardiac cycle: retrograde flows during cycle ergometry
    Green, D
    Cheetham, C
    Reed, C
    Dembo, L
    O'Driscoll, G
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (01) : 361 - 368
  • [9] Impaired progenitor cell activity in age-related endothelial dysfunction
    Heiss, C
    Keymel, S
    Niesler, U
    Ziemann, J
    Kelm, M
    Kalka, C
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (09) : 1441 - 1448
  • [10] Impaired endothelial function with essential hypertension assessed by ultrasonography
    Iiyama, K
    Nagano, M
    Yo, Y
    Nagano, N
    Kamide, K
    Higaki, J
    Mikami, H
    Ogihara, T
    [J]. AMERICAN HEART JOURNAL, 1996, 132 (04) : 779 - 782