Multi-slice technology in computed tomography

被引:53
作者
Dawson, P [1 ]
Lees, WR [1 ]
机构
[1] UCL Hosp, Dept Imaging, London, England
关键词
helical/spiral; computed tomography; multi-slice;
D O I
10.1053/crad.2000.0651
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multi-slice systems represent a considerable advance in CT and will assure the future of the technique for many years to come. This article describes this new technology, indicating its provenance and its position in the evolution of CT. While it does not seek to be a physics and engineering text, enough detail of these are given to allow an informed discussion of the many advantages and a few potential problems associated with the technology. A discussion of a number of applications and a brief consideration of contrast enhancement regimens and the possible need for their modification are presented. (C) 2001 The Royal College of Radiologists.
引用
收藏
页码:302 / 309
页数:8
相关论文
共 13 条
[1]  
BRINK JA, 1995, RADIOL CLIN N AM, V33, P825
[2]  
Flohr T, 1999, RADIOLOGY, V213P, P317
[3]  
Fuchs TO, 1999, RADIOLOGY, V213P, P317
[4]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[5]   The effect of helical pitch and beam collimation on the lesion contrast and slice profile in helical CT imaging [J].
Hu, H ;
Fox, SH .
MEDICAL PHYSICS, 1996, 23 (12) :1943-1954
[6]   Four multidetector-row helical CT: Image quality and volume coverage speed [J].
Hu, H ;
He, HD ;
Foley, WD ;
Fox, SH .
RADIOLOGY, 2000, 215 (01) :55-62
[7]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[8]   Dosimetry for optimisation of patient protection in computed tomography [J].
Jessen, KA ;
Shrimpton, PC ;
Geleijns, J ;
Panzer, W ;
Tosi, G .
APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) :165-172
[9]  
Kachelriess M, 1999, RADIOLOGY, V213P, P283
[10]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183