Three-dimensional ultrasound examination of the fetal hands: normal and abnormal

被引:38
作者
Budorick, NE [1 ]
Pretorius, DH [1 ]
Johnson, DD [1 ]
Tartar, MK [1 ]
Lou, KV [1 ]
Nelson, TR [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
关键词
ultrasound; three-dimensional; technology; fetus; skeletal system; abnormality;
D O I
10.1046/j.1469-0705.1998.12040227.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose To assess particular features of fetal hand evaluation using three-dimensional ultrasound, and to determine whether any advantage is offered by three-dimensional over two-dimensional ultrasound in fetal hand evaluation. Methods Three-dimensional fetal data were collected prospectively from 44 hands in 40 fetuses from a predominantly high-risk patient population. All had a concurrent two-dimensional ultrasound examination of the hands. Diagnoses from two- and three-dimensional ultrasound examinations were compared and additional information from the three-dimensional volume assessment was noted. Three-dimensional assessment of distal forearm bones, wrist position, finger configuration and number of metacarpals and digits was recorded. Results Hands were appropriately identified as normal (32/32) or abnormal (12/12) by both two- and three-dimensional ultrasound. Three-dimensional ultrasound provided additional information when compared to two-dimensional ultrasound in both normal and abnormal hands, including the provision of three orthogonal planes with one volume acquisition, allowing rotation of the volume so that hands could be evaluated in planes not possible during two-dimensional imaging, assessment of a hand with loosely curled fingers as normal, the ability to evaluate thumb and fingers simultaneously, and improved assessment of abnormal hands. Conclusions Three-dimensional ultrasound offers the potential to provide greater information in fetal hand evaluation for both normal and abnormal hands.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 23 条
[1]  
*AM COLL OBST GYN, 1993, AM COLL OBST GYN TEC, V187, P1
[2]  
*AM I ULTR MED, 1994, GUID PERF ANT OBST U
[3]   SONOGRAPHIC DETECTION OF FETUSES WITH TRISOMIE-13 AND TRISOMIE-18 - ACCURACY AND LIMITATIONS [J].
BENACERRAF, BR ;
MILLER, WA ;
FRIGOLETTO, FD .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1988, 158 (02) :404-409
[4]   ABNORMAL FACIAL FEATURES AND EXTREMITIES IN HUMAN TRISOMY SYNDROMES - PRENATAL US APPEARANCE [J].
BENACERRAF, BR ;
FRIGOLETTO, FD ;
GREENE, MF .
RADIOLOGY, 1986, 159 (01) :243-246
[5]  
BONILLAMUSOLES F, 1995, J ULTRAS MED, V14, P757
[6]   ABNORMALITIES OF THE HANDS AND FEET IN THE FETUS - SONOGRAPHIC FINDINGS [J].
BROMLEY, B ;
BENACERRAF, B .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) :1239-1243
[7]  
BUDORICK NE, 1995, RADIOLOGY, V197, P197
[8]   A RANDOMIZED TRIAL OF PRENATAL ULTRASONOGRAPHIC SCREENING - IMPACT ON THE DETECTION, MANAGEMENT, AND OUTCOME OF ANOMALOUS FETUSES [J].
CRANE, JP ;
LEFEVRE, ML ;
WINBORN, RC ;
EVANS, JK ;
EWIGMAN, BG ;
BAIN, RP ;
FRIGOLETTO, FD ;
MCNELLIS, D ;
KANE, D ;
BOYD, L ;
CORNELISON, S ;
PLATTNER, M ;
CRAMER, DW ;
HARLOW, BL ;
TURLINGTON, T ;
BURROWS, PK ;
YAFFE, S ;
CATZ, C ;
QUILLIGAN, EJ ;
HADLOCK, F ;
HOBBINS, JC ;
WILLIAMS, G .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (02) :392-399
[9]   EFFECT OF PRENATAL ULTRASOUND SCREENING ON PERINATAL OUTCOME [J].
EWIGMAN, BG ;
CRANE, JP ;
FRIGOLETTO, FD ;
LEFEVRE, ML ;
BAIN, RP ;
MCNELLIS, D .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (12) :821-827
[10]   MEASUREMENT OF LIMB CIRCUMFERENCES WITH 3-DIMENSIONAL ULTRASOUND FOR FETAL WEIGHT ESTIMATION [J].
FAVRE, R ;
NISAND, G ;
BETTAHAR, K ;
GRANGE, G ;
NISAND, I .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1993, 3 (03) :176-179