Which dialyser membrane to choose?

被引:52
作者
Bouré, T [1 ]
Vanholder, R [1 ]
机构
[1] Ghent Univ Hosp, Dept Internal Med, Div Nephrol, B-9000 Ghent, Belgium
关键词
bioincompatible; cellulose; dialyser; high-flux; low-flux; synthetic;
D O I
10.1093/ndt/gfg508
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 [基础医学]; 1002 [临床医学]; 100602 [中西医结合临床];
摘要
引用
收藏
页码:293 / 296
页数:4
相关论文
共 39 条
[1]
Relationship of dialysis membrane and cause-specific mortality [J].
Bloembergen, WE ;
Hakim, RM ;
Stannard, DC ;
Held, PJ ;
Wolfe, RA ;
Agodoa, LYC ;
Port, FK .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 33 (01) :1-10
[2]
HYPERHOMOCYSTEINEMIA AND TRADITIONAL CARDIOVASCULAR-DISEASE RISK-FACTORS IN END-STAGE RENAL-DISEASE PATIENTS ON DIALYSIS - A CASE-CONTROL STUDY [J].
BOSTOM, AG ;
SHEMIN, D ;
LAPANE, KL ;
MILLER, JW ;
SUTHERLAND, P ;
NADEAU, M ;
SEYOUM, E ;
HARTMAN, W ;
PRIOR, R ;
WILSON, PWF ;
SELHUB, J .
ATHEROSCLEROSIS, 1995, 114 (01) :93-103
[3]
Cytokine filtration and adsorption during pre- and postdilution hemofiltration in four different membranes [J].
Bouman, CSC ;
van Olden, RW ;
Stoutenbeek, CP .
BLOOD PURIFICATION, 1998, 16 (05) :261-268
[4]
CHANDRAN PKG, 1993, J AM SOC NEPHROL, V4, P1199
[5]
Churchill DN, 1995, NEPHROL DIAL TRANSPL, V10, P52
[6]
GRANULOCYTE ACTIVATION AND ADHESION MOLECULES DURING HEMODIALYSIS WITH CUPROPHANE AND A HIGH-FLUX BIOCOMPATIBLE MEMBRANE [J].
COMBE, C ;
POURTEIN, M ;
DEPRECIGOUT, V ;
BAQUEY, A ;
MOREL, D ;
POTAUX, L ;
VINCENDEAU, P ;
BEZIAN, JH ;
APARICIO, M .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (03) :437-442
[7]
HEMODIALYSIS LEUKOPENIA - PULMONARY VASCULAR LEUKOSTASIS RESULTING FROM COMPLEMENT ACTIVATION BY DIALYZER CELLOPHANE MEMBRANES [J].
CRADDOCK, PR ;
FEHR, J ;
DALMASSO, AP ;
BRIGHAM, KL ;
JACOB, HS .
JOURNAL OF CLINICAL INVESTIGATION, 1977, 59 (05) :879-888
[8]
Leukocyte CD14 and CD45 expression during hemodialysis: Polysulfone versus cuprophane [J].
Dhondt, AW ;
Vanholder, RC ;
Waterloos, MAF ;
Glorieux, GL ;
Ringoir, SMG .
NEPHRON, 1996, 74 (02) :342-348
[9]
Effect of dialysis dose and membrane flux in maintenance hemodialysis. [J].
Eknoyan, G ;
Beck, GJ ;
Cheung, AK ;
Daugirdas, JT ;
Greene, T ;
Kusek, JW ;
Allon, M ;
Bailey, J ;
Delmez, JA ;
Depner, TA ;
Dwyer, JT ;
Levey, AS ;
Levin, NW ;
Milford, E ;
Ornt, DB ;
Rocco, MV ;
Schulman, G ;
Schwab, SJ ;
Teehan, BP ;
Toto, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (25) :2010-2019
[10]
European Best Practice Guidelines Expert Group on Hemodialysis European Renal Association, 2002, NEPHROL DIAL TRAN S7, V17, P32