Tissue-engineered vascular autograft: Inferior vena cava replacement in a dog model

被引:142
作者
Watanabe, M
Shin'Oka, T
Tohyama, S
Hibino, N
Konuma, T
Matsumura, G
Kosaka, Y
Ishida, T
Imai, Y
Yamakawa, M
Ikada, Y
Morita, S
机构
[1] Tokyo Womens Med Univ, Heart Inst Japan, Dept Pediat Cardiovasc Surg, Shinjuku Ku, Tokyo, Japan
[2] Yamagata Univ, Dept Pathol, Yamagata 990, Japan
[3] Suzuka Univ Med Sci, Suzuka, Japan
[4] Gunze LTD, Dept Res & Dev, Kyoto, Japan
来源
TISSUE ENGINEERING | 2001年 / 7卷 / 04期
关键词
D O I
10.1089/10763270152436481
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Tissue-engineered vascular autografts (TEVAs) were made by seeding 4-6 x 10(6) of mixed cells obtained from femoral veins of mongrel dogs onto tube-shaped biodegradable polymer scaffolds composed of a polyglycolid acid (PGA) nonwoven fabric sheet and a copolymer of L-lactide and caprolactone (n = 4). After 7 days, the inferior vena cavas (IVCs) of the same dogs were replaced with TEVAs. After 3, 4, 5, and 6 months, angiographies were performed, and the dogs were sacrificed. The implanted TEVAs were examined both grossly and immunohistologically. The implanted TEVAs showed no evidence of stenosis or dilatation. No thrombus was found inside the TEVAs, even without any anticoagulation therapy. Remnants of the polymer scaffolds were not observed in all specimens, and the overall gross appearance similar to that of native IVCs. Immunohistological staining revealed the presence of factor VIII positive nucleated cells at the luminal surface of the TEVAs. In addition, lesions were observed where alpha -smooth muscle actin and desmin positive cells existed. Implanted TEVAs contained a sufficient amount of extracellular matrix, and showed neither occlusion nor aneurysmal formation. In addition, endothelial cells were found to line the luminal surface of each TEVA. These results strongly suggest that "ideal" venous grafts with antithrombogenicity can be produced.
引用
收藏
页码:429 / 439
页数:11
相关论文
共 23 条
[1]  
BRAUNWALD E, 1992, HEART DISEASE TXB CA, P1007
[2]  
FRAZZA E J, 1971, Journal of Biomedical Materials Research Biomedical Materials Symposium, V1, P43
[3]   NEOCARTILAGE FORMATION INVITRO AND INVIVO USING CELLS CULTURED ON SYNTHETIC BIODEGRADABLE POLYMERS [J].
FREED, LE ;
MARQUIS, JC ;
NOHRIA, A ;
EMMANUAL, J ;
MIKOS, AG ;
LANGER, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (01) :11-23
[4]   CULTURED HUMAN-EPIDERMIS CELLS PRODUCE CELL-ASSOCIATED INTERLEUKIN-1-LIKE PROSTAGLANDIN-E2-STIMULATING AND COLLAGENASE-STIMULATING FACTORS [J].
HAUSER, C ;
SAURAT, JH ;
JAUNIN, F ;
SIZONENKO, S ;
DAYER, JM .
BIOCHIMICA ET BIOPHYSICA ACTA, 1985, 846 (03) :350-355
[5]   Venous reconstruction using hybrid vascular tissue composed of vascular cells and collagen: Tissue regeneration process [J].
Hirai, J ;
Matsuda, T .
CELL TRANSPLANTATION, 1996, 5 (01) :93-105
[6]   Outcome of subcutaneous islet transplantation improved by polymer device [J].
Juang, JH ;
BonnerWeir, S ;
Ogawa, Y ;
Vacanti, JP ;
Weir, GC .
TRANSPLANTATION, 1996, 61 (11) :1557-1561
[7]  
KIRKLIN J, 1993, CARDIAC SURG, P885
[8]   NEW METHODS OF DRUG DELIVERY [J].
LANGER, R .
SCIENCE, 1990, 249 (4976) :1527-1533
[9]   TISSUE ENGINEERING [J].
LANGER, R ;
VACANTI, JP .
SCIENCE, 1993, 260 (5110) :920-926
[10]   In vitro release of trypanocidal drugs from biodegradable implants based on poly(ε-caprolactone) and poly(D,L-lactide) [J].
Lemmouchi, Y ;
Schacht, E ;
Lootens, C .
JOURNAL OF CONTROLLED RELEASE, 1998, 55 (01) :79-85