A digital beamformer for high-frequency annular arrays

被引:19
作者
Brown, JA [1 ]
Lockwood, GR [1 ]
机构
[1] Queens Univ, Dept Phys, Kingston, ON K7L 3N6, Canada
关键词
D O I
10.1109/TUFFC.2005.1509785
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Digital transmit and receive beamformers for a 45-MHz, 7-element annular array are described. The transmit beamformer produces 0- to 80-Vpp monocycle pulses with a timing error of less than +/- 125 ps. Up to four adjustable transmit focal zones can be selected. The dynamic receive beamformer uses a variable frequency sampling technique in which the frequency of analog-to-digital conversion on each channel is adjusted as the signals are received. The variable frequency clock signals required to trigger analog-to-digital conversion are obtained using a pair of high-frequency field-programmable gate arrays and a precision quartz oscillator. The gate arrays are also used to sum the digitized signals. A maximum receive beamformer timing error of less than 900 ps was obtained on each channel. The performance of the combined transmit and receive beamformer was tested by imaging wire phantoms. Images of CD-1 mice were also generated. The system produced images with a dynamic range of 60 dB.
引用
收藏
页码:1262 / 1269
页数:8
相关论文
共 13 条
[1]   AN ANNULAR ARRAY SYSTEM FOR HIGH-RESOLUTION BREAST ECHOGRAPHY [J].
ARDITI, M ;
TAYLOR, WB ;
FOSTER, FS ;
HUNT, JW .
ULTRASONIC IMAGING, 1982, 4 (01) :1-31
[2]   TRANSIENT FIELDS OF CONCAVE ANNULAR ARRAYS [J].
ARDITI, M ;
FOSTER, FS ;
HUNT, JW .
ULTRASONIC IMAGING, 1981, 3 (01) :37-61
[3]   Design and fabrication of annular arrays for high-frequency ultrasound [J].
Brown, JA ;
Démoré, CEM ;
Lockwood, GR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (08) :1010-1017
[4]   A low-cost, high-performance pulse generator for ultrasound imaging [J].
Brown, JA ;
Lockwood, GR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (06) :848-851
[5]   In vivo imaging of embryonic development in the mouse eye by ultrasound biomicroscopy [J].
Foster, FS ;
Zhang, MY ;
Duckett, AS ;
Cucevic, V ;
Pavlin, CJ .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (06) :2361-2366
[6]  
Foster FS, 2000, ULTRASON, P1633, DOI 10.1109/ULTSYM.2000.921637
[7]   A DIGITAL ANNULAR ARRAY PROTOTYPE SCANNER FOR REALTIME ULTRASOUND IMAGING [J].
FOSTER, FS ;
LARSON, JD ;
PITTARO, RJ ;
CORL, PD ;
GREENSTEIN, AP ;
LUM, PK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (07) :661-672
[8]   THE DESIGN OF PROTECTION CIRCUITRY FOR HIGH-FREQUENCY ULTRASOUND IMAGING-SYSTEMS [J].
LOCKWOOD, GR ;
HUNT, JW ;
FOSTER, FS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (01) :48-55
[9]   A COMPARISON OF EFFICIENT BEAMFORMING ALGORITHMS [J].
MUCCI, RA .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1984, 32 (03) :548-558
[10]   PERITONEAL-LAVAGE IN PEDIATRIC-PATIENTS SUSTAINING BLUNT ABDOMINAL-TRAUMA - A REAPPRAISAL [J].
POWELL, RW ;
GREEN, JB ;
OCHSNER, MG ;
BARTTELBORT, SW ;
SHACKFORD, SR ;
SISE, MJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1987, 27 (01) :6-10