Current phase comparison pilot scheme for distributed generation networks protection

被引:56
作者
El Halabi, N. [1 ]
Garcia-Gracia, M. [1 ]
Borroy, J. [1 ]
Villa, J. L. [2 ]
机构
[1] Ctr Res Energy Resources & Consumpt, CIRCE, Zaragoza 50018, Spain
[2] Univ Zaragoza, Dept Elect Engn, E-50009 Zaragoza, Spain
关键词
Distributed generation; Protection schemes; Distribution networks protection; Phase jump; DIFFERENTIAL PROTECTION; IMPROVEMENT; TRANSIENT; SYSTEMS;
D O I
10.1016/j.apenergy.2011.05.048
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The trends of the actual distribution networks are moving toward a high penetration of distributed generation and power electronics converters. These technologies modify contribution-to-fault current magnitudes and raise concern about new protection parameters settings to accurately detect faults on distribution networks. This paper proposes a differential phase jump pilot scheme to detect faulted branches in distribution networks. The aim of the proposed scheme is to provide an efficient algorithm with functions of fault detection and isolation, which are part of the self-healing functions used for smart grids. The proposed scheme is based on the current phase jump measured in each node with fault inception. Then, by comparing the phase jump obtained with the prefault conditions and rate changes, it determines the fault direction enabling a trip signal to the corresponding nodes to isolate the branch under fault. A distribution network has been modeled in PSCAD/EMTDC program to verify the proposed algorithm, taking into account distributed generation provided by both wind turbines (doubly fed induction generator and permanent magnet generator with full converter) and solar photovoltaic installations. The behavior of the current phase jump has been studied for both generation and load nodes. This algorithm is not affected by the magnitude of current and voltage and has been tested varying fault location and resistance along the modeled distribution network. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4563 / 4569
页数:7
相关论文
共 23 条
[1]   Laboratory Investigation of Using Wi-Fi Protocol for Transmission Line Differential Protection [J].
Abdel-Latif, K. M. ;
Eissa, M. M. ;
Ali, A. S. ;
Malik, O. P. ;
Masoud, M. E. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) :1087-1094
[2]   Distributed generation:: a definition [J].
Ackermann, T ;
Andersson, G ;
Söder, L .
ELECTRIC POWER SYSTEMS RESEARCH, 2001, 57 (03) :195-204
[3]  
[Anonymous], 2005, P CIGRE 5 SO AFR REG
[4]  
[Anonymous], 2009, COMPUTER RELAYING PO
[5]  
[Anonymous], 2006, PSCAD V4 2
[6]   Development of adaptive protection scheme for distribution systems with high penetration of distributed generation [J].
Brahma, SM ;
Girgis, AA .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :56-63
[7]   Distance relaying of 11Kv circuits to increase the installed capacity of distributed generation [J].
Chilvers, I ;
Jenkins, N ;
Crossley, P .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2005, 152 (01) :40-46
[8]  
Comech M. Paz, 2010, Distributed Generation, P289
[9]   Aggregate modelling of wind farms containing full-converter wind turbine generators with permanent magnet synchronous machines: transient stability studies [J].
Conroy, J. ;
Watson, R. .
IET RENEWABLE POWER GENERATION, 2009, 3 (01) :39-52
[10]   Fault location for underground distribution feeders: An extended impedance-based formulation with capacitive current compensation [J].
Filomena, Andre D. ;
Resener, Mariana ;
Salim, Rodrigo H. ;
Bretas, Arturo S. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2009, 31 (09) :489-496