Whole cell- and protein-based biosensors for the detection of bioavailable heavy metals in environmental samples

被引:190
作者
Corbisier, P
van der Lelie, D
Borremans, B
Provoost, A
de Lorenzo, V
Brown, NL
Lloyd, JR
Hobman, JL
Csöregi, E
Johansson, G
Mattiasson, B
机构
[1] Vlaamse Instelling Technol Onderzoek, B-2400 Mol, Belgium
[2] Univ Birmingham, Sch Biol Sci, Birmingham B15 2TT, W Midlands, England
[3] Lund Univ, Ctr Chem & Chem Engn, Dept Biotechnol, S-22100 Lund, Sweden
关键词
heavy metals; bioavailability; biosensors; affinity sensors; capacitance measurements;
D O I
10.1016/S0003-2670(98)00725-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The principal goal of this work was to establish the feasibility of two biosensor technologies with enhanced specificity and selectivity for the detection of several bioavailable heavy metals in environmental samples. Two parallel strategies have been followed. The first approach was to construct whole cell bacterial biosensors that emit a bioluminescent or fluorescent signal in the presence of a biologically available heavy metal. The molecular basis of sigma-54 promoters as sensing elements of environmental pollutants has been determined and a number of metal-induced promoter regions have been identified, sequenced and cloned as promoter cassettes. The specificity of the promoter cassettes has been determined using luxCDABE reporter systems. Whole cell-biosensors containing metal-induced lux reporter systems have been incorporated into different matrices for their later immobilisation on optic fibres and characterised in terms of their sensitivity and storage capacity. The second type of censors was based on the direct interaction between metal-binding proteins and heavy metal ions. In this case, the capacitance changes of the proteins, such as synechoccocal metallothionein (as a GST-SmtA fusion protein) and the mercury regulatory protein, MerR, were detected in the presence of femtomolar to millimolar metal ion concentrations. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:235 / 244
页数:10
相关论文
共 26 条
[1]   Capacitance measurements of antibody-antigen interactions in a flow system [J].
Berggren, C ;
Johansson, G .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3651-3657
[2]  
BORREMANS B, 1997, P 6 INT C PSEUD MOL, pR9
[3]   MOLECULAR-GENETICS AND TRANSPORT ANALYSIS OF THE COPPER-RESISTANCE DETERMINANT (PCO) FROM ESCHERICHIA-COLI PLASMID PRJ1004 [J].
BROWN, NL ;
BARRETT, SR ;
CAMAKARIS, J ;
LEE, BTO ;
ROUCH, DA .
MOLECULAR MICROBIOLOGY, 1995, 17 (06) :1153-1166
[4]   GREEN FLUORESCENT PROTEIN AS A MARKER FOR GENE-EXPRESSION [J].
CHALFIE, M ;
TU, Y ;
EUSKIRCHEN, G ;
WARD, WW ;
PRASHER, DC .
SCIENCE, 1994, 263 (5148) :802-805
[5]   PERMISSIVE SITES AND TOPOLOGY OF AN OUTER-MEMBRANE PROTEIN WITH A REPORTER EPITOPE [J].
CHARBIT, A ;
RONCO, J ;
MICHEL, V ;
WERTS, C ;
HOFNUNG, M .
JOURNAL OF BACTERIOLOGY, 1991, 173 (01) :262-275
[6]  
Corbisier P, 1996, ENVIRON TOXIC WATER, V11, P171, DOI 10.1002/(SICI)1098-2256(1996)11:3<171::AID-TOX1>3.3.CO
[7]  
2-Z
[8]  
CORBISIER P, 1994, BIOLUMINESCENCE CHEM, P151
[9]   Metalloregulation in vitro of the aerobactin promoter of Escherichia coli by the Fur (ferric uptake regulation) protein [J].
Escolar, L ;
deLorenzo, V ;
PerezMartin, J .
MOLECULAR MICROBIOLOGY, 1997, 26 (04) :799-808
[10]   DNA DISTORTION ACCOMPANIES TRANSCRIPTIONAL ACTIVATION BY THE METAL-RESPONSIVE GENE-REGULATORY PROTEIN MERR [J].
FRANTZ, B ;
OHALLORAN, TV .
BIOCHEMISTRY, 1990, 29 (20) :4747-4751