Simultaneous determination of As, Hg, Sb, Se and Sn in sediments by slurry sampling axial view inductively coupled plasma optical emission spectrometry using on-line chemical vapor generation with internal standardization

被引:43
作者
dos Santos, EJ
Herrmann, AB
Frescura, VLA
Curtius, AJ [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040090 Florianopolis, SC, Brazil
[2] Inst Tecnol Parana, BR-81350010 Curitiba, Parana, Brazil
关键词
D O I
10.1039/b502964c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid method for the simultaneous determination of As, Hg, Sb, Se and Sn in sediment slurries by axial view optical emission inductively coupled plasma using on-line chemical vapor generation and Ge(IV) as internal standard is proposed. The sample ( 15 - 30 mg with particle size <= 120 mu m) is treated with aqua regia for 30 min in an ultrasonic bath. After adding 50 mg L-1 of Ge( IV), the volume is made up to 15 mL with deionized water. Ge( IV) at 219.871 nm was used as the internal standard for As and Se. The concentrations of NaBH4 and of HCl used for the chemical vapor generation were optimized by factorial analysis, using an aqueous standard solution of the analytes and a slurry of a certified sediment. Two ultrasonic systems with two different frequencies ( 25 kHz and 40 kHz) were tested, the more powerful one being adopted, since it provided more efficient analyte extraction to the liquid phase. The obtained detection limits (LODs), for 20 mg of sample, were: 0.5 mu g g(-1) (As), 0.1 mu g g(-1) (Hg), 0.2 mu g g(-1) (Sb), 0.1 mu g g(-1) (Se) and 6 mu g g(-1) (Sn). The obtained results for 4 certified sediments were in agreement with the certified values, according to the t-test, for a confidence level of 95%, with the following relative standard deviation ranges: 2 - 11% ( As), 2 - 4% ( Hg), 4 - 12% ( Sb), 5 - 15% ( Se) and 3 - 15% ( Sn), all adequate for slurry sampling.
引用
收藏
页码:538 / 543
页数:6
相关论文
共 24 条
[1]   Possibilities and limits of the simultaneous determination of As, Bi, Ge, Sb, Se, and Sn by flow injection-hydride generation-inductively coupled plasma-time-of-flight mass spectrometry (FI-HG-ICP-TOFMS) [J].
Abrankó, L ;
Stefánka, Z ;
Fodor, P .
ANALYTICA CHIMICA ACTA, 2003, 493 (01) :13-21
[2]   Ultrasonic extraction as a sample preparation technique for elemental analysis by atomic spectrometry [J].
Ashley, K ;
Andrews, RN ;
Cavazos, L ;
Demange, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (10) :1147-1153
[3]  
BAIRD C, 1997, QUIMICA AMBIENTAL, P402
[4]  
Brodie K., 1983, VARIAN INSTRUM WO AA, P1
[5]  
Cava-Montesinos P, 2004, TALANTA, V62, P175, DOI [10.1016/S0039-9140(03)00411-9, 10.1016/S0039-9140k(03)00411-9]
[6]   Slurry nebulization in plasmas [J].
Ebdon, L ;
Foulkes, M ;
Sutton, K .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) :213-229
[7]   Atomic spectrometry update. Advances in atomic emission, absorption and fluorescence spectrometry and related techniques [J].
Evans, EH ;
Day, JA ;
Fisher, A ;
Price, WJ ;
Smith, CMM ;
Tyson, JF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (06) :775-812
[8]   Selection of internal standards in inductively coupled plasma atomic emission spectrometry by principal component analysis [J].
Grotti, M ;
Magi, E ;
Leardi, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (03) :274-281
[9]   Results of a complex round robin test with four river sediments [J].
Heininger, P ;
Pelzer, J ;
Henrion, R ;
Henrion, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (3-4) :344-347
[10]   Real-time internal standardization with an axially-viewed inductively coupled plasma for optical emission spectrometry [J].
Ivaldi, JC ;
Tyson, JF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (12) :1443-1450