Potentiometric stripping analysis (PSA) for monitoring of antimony in samples of vegetation from a mining area

被引:2
作者
Gordillo, MCT
Gil, EP [1 ]
González, MAR
Murciego, AM
Ostapczuk, P
机构
[1] Univ Extremadura, Dept Quim Analit & Electroquim, E-06071 Badajoz, Spain
[2] Univ Extremadura, Area Cristalog & Mineral, E-06071 Badajoz, Spain
[3] Res Ctr Julich, D-52425 Julich, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 370卷 / 04期
关键词
D O I
10.1007/s002160100809
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric stripping analysis (PSA) method has been developed and checked for the fast and reliable determination of antimony in vegetation samples of Cistus ladanifer from a mining area in Badajoz, Southwest Spain. The method, modified from previous PSA methods for Sb in environmental samples, is based on dry ashing of the homogenized leaves, dissolution in hydrochloric acid, and PSA analysis on a mercury film plated on to a glassy carbon disk electrode. The influence of experimental variables such as the deposition potential, the deposition time, the signal stability and the calibration parameters, has been investigated. The method has been compared with an independent technique (instrumental neutron activation analysis) by analysis of standards and reference materials and comparison of the results. As a result of automation of the PSA equipment, the proposed method enables unattended analysis of 20 digested samples in a total time of 2 h, thus providing a useful tool for Sb monitoring of a large number of samples.
引用
收藏
页码:434 / 437
页数:4
相关论文
共 25 条
[1]   Anodic stripping potentiometric determination of antimony on a combined electrode [J].
Adeloju, SB ;
Young, TM ;
Jagner, D ;
Batley, GE .
ANALYST, 1998, 123 (09) :1871-1874
[2]   ANODIC-STRIPPING POTENTIOMETRIC DETERMINATION OF ANTIMONY IN ENVIRONMENTAL MATERIALS [J].
ADELOJU, SB ;
YOUNG, TM .
ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) :225-232
[3]   DETERMINATION OF DISSOLVED INORGANIC ANTIMONY(V) AND ANTIMONY(III) SPECIES IN NATURAL-WATERS BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
APTE, SC ;
HOWARD, AG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (03) :221-225
[4]   Determination of antimony(III) and antimony(V) in copper plant electrolyte by anodic stripping voltammetry [J].
Bond, AM ;
Kratsis, S ;
Newman, OMG .
ELECTROANALYSIS, 1997, 9 (09) :681-684
[5]   Off-line and on-line differential pulse anodic stripping voltammetric techniques for the determination of antimony(III), and antimony(v) in zinc plant electrolyte [J].
Bond, AM ;
Kratsis, S ;
Newman, OMG ;
Pfund, BV .
ELECTROANALYSIS, 1997, 9 (01) :13-18
[6]   ANODIC-STRIPPING VOLTAMMETRIC DETERMINATION OF ANTIMONY IN GUNSHOT RESIDUE [J].
BRINER, RC ;
CHOUCHOIY, S ;
WEBSTER, RW ;
POPHAM, RE .
ANALYTICA CHIMICA ACTA, 1985, 172 (JUN) :31-37
[7]   DETERMINATION OF ANTIMONY IN SEAWATER BY CATHODIC STRIPPING VOLTAMMETRY [J].
CAPODAGLIO, G ;
VAN DEN BERG, CMG ;
SCARPONI, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 235 (1-2) :275-286
[8]   APPLICATION OF ISOTOPE-DILUTION ANALYSIS INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY TO THE PRECISE DETERMINATION OF SILVER AND ANTIMONY IN PURE COPPER [J].
CHIBA, K ;
INAMOTO, I ;
SAEKI, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :115-119
[9]   DIRECT AND SIMULTANEOUS DETERMINATIONS OF ZN, CD, PB, CU, SB AND BI DISSOLVED IN SEA-WATER BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY WITH A HANGING MERCURY DROP ELECTRODE [J].
GILLAIN, G ;
DUYCKAERTS, G ;
DISTECHE, A .
ANALYTICA CHIMICA ACTA, 1979, 106 (01) :23-37
[10]  
GUNTINAS MBD, 1991, ANAL CHIM ACTA, V252, P161