Determination of γ-globulin at nanogram levels by its enhancement effect on the resonance light scattering of functionalized HgS nanoparticles

被引:29
作者
Wang, LY [1 ]
Wang, L [1 ]
Dong, L [1 ]
Hu, YL [1 ]
Xia, TT [1 ]
Chen, HQ [1 ]
Li, L [1 ]
Zhu, CQ [1 ]
机构
[1] Anhui Normal Univ, Coll Chem & Mat Sci, Wuhu 24100, Peoples R China
关键词
resonance light scattering; gamma-globulin; nano-HgS;
D O I
10.1016/j.talanta.2003.07.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel assay of gamma-globulin (gamma-IgG) with a sensitivity at the nanogram level is proposed based on the measurement of enhanced resonance light-scattering (RLS) signals resulting from the interaction of functionalized nano-HgS with gamma-globulin. At pH 5.03, the RLS signals of functionalized nano-HgS were greatly enhanced by gamma-globulin in the region of 200-700 nm characterized by the peak around 362 nm. Linear relationship can be established between the enhanced RLS intensity and gamma-globulin concentration in the range of 10-140 ng ml(-1). The limit of detection is 2.71 ng ml(-1). Based on this, a new direct quantitative determination method for gamma-globulin in blood serum samples without separation of human serum albumin (HSA) is established. The contents of gamma-IgG in blood serum samples were determined with recovery of 95.7-102.5% and R.S.D. of 1.6-2.4%. This method is proved to be very sensitive, rapid, simple and tolerance of most interfering substances. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:237 / 240
页数:4
相关论文
共 24 条
[1]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[2]   Semiconductor nanocrystals as fluorescent biological labels [J].
Bruchez, M ;
Moronne, M ;
Gin, P ;
Weiss, S ;
Alivisatos, AP .
SCIENCE, 1998, 281 (5385) :2013-2016
[3]   Quantum dot bioconjugates for ultrasensitive nonisotopic detection [J].
Chan, WCW ;
Nie, SM .
SCIENCE, 1998, 281 (5385) :2016-2018
[4]   Study of the reaction of proteins with Beryllon II-AlIII by the Rayleigh light scattering technique and its application [J].
Dong, LJ ;
Jia, RP ;
Li, QF ;
Chen, XG ;
Hu, ZD .
ANALYST, 2001, 126 (05) :707-711
[5]  
FLORES PR, 1978, ANAL LETT, V74, P605
[6]   Improved o-sulfophenylfluorone-titanium(IV) complex method for total urinary protein assay [J].
Fujita, Y ;
Mori, I ;
Matsuo, T .
ANALYTICAL SCIENCES, 1997, 13 (03) :513-516
[7]   THE DETERMINATION OF A SMALL AMOUNT OF BIOLOGICAL CONSTITUENT BY THE USE OF CHEMI-LUMINESCENCE .13. HIGH SENSITIVE METAL CHELATE AFFINITY-CHROMATOGRAPHY [J].
HARA, T ;
TSUKAGOSHI, K ;
YOSHIDA, T .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1988, 61 (08) :2779-2783
[8]   THE DETERMINATION OF A SMALL AMOUNT OF BIOLOGICAL CONSTITUENT BY THE USE OF CHEMI-LUMINESCENCE .14. THE FLOW-INJECTION ANALYSIS OF PROTEIN USING ULTRASONIC CHEMI-LUMINESCENCE OF LUMINOL [J].
HARA, T ;
NAKATSU, K ;
ARAI, A ;
YOSHIDA, T ;
TSUKAGOSHI, K .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1988, 61 (08) :2996-2998
[10]  