Absolute, soft x-ray calorimetry on the Z facility at Sandia National Laboratories (invited)

被引:16
作者
Fehl, DL [1 ]
Muron, DJ [1 ]
Leeper, RJ [1 ]
Chandler, GA [1 ]
Deeney, C [1 ]
Stygar, WA [1 ]
Spielman, RB [1 ]
机构
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
关键词
D O I
10.1063/1.1149515
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Simple and reliable x-ray fluence measurements, in addition to time-resolved diagnostics, are needed to understand the physics of hot Z-pinch plasmas. A commercially available laser calorimeter has been modified for measuring soft x-ray fluence from the Z facility at Sandia National Laboratories. The x-ray absorber of this calorimeter is an aluminum disk, attached to a two-dimensional thermopile and surrounded by an isoperibol shroud. The time integral and the maximum of the thermopile voltage signal are both proportional to the x-ray energy deposited. Data are collected for 90 s, and the instrument has, thus far, been used in the 1-25 mJ range. A wider dynamic measuring range for x-ray fluence (energy/area) can be achieved by varying the area of the defining aperture. The calorimeter is calibrated by an electrical substitution method. Calibrations are performed before and after each x-ray experiment on the Z facility. The calibration of the time integral of the thermopile voltage versus energy deposited (or the peak of thermopile voltage versus energy deposited) is linear with zero intercept at the 95% confidence level. The irreproducibility of the calibration is < 2%, and the imprecision in the measurement of the incident x-ray energy (inferred from signal noise and the calibration) is estimated to be similar to 0.9 mJ (95% confidence level). The systematic uncertainty (inaccuracy), due to correctable baseline shifts, is estimated at +/- 10%. Comparisons have been made of the calorimeter to time-resolved x-ray diagnostics, e.g., bolometers and x-ray diode arrays, by integrating the flux measured by such instruments over time. (C) 1999 American Institute of Physics. [S0034-6748(99)70101-2].
引用
收藏
页码:270 / 275
页数:6
相关论文
共 10 条
[1]   ICF TARGET DIAGNOSTICS ON PBFA-II (INVITED) [J].
CHANDLER, GA ;
AUBERT, J ;
BAILEY, J ;
CARLSON, A ;
DERZON, D ;
DERZON, M ;
DUKART, R ;
HUMPHREYS, R ;
HUNTER, J ;
JOHNSON, DJ ;
MATZEN, MK ;
MOATS, A ;
OLSON, R ;
PANTUSO, J ;
ROCKETT, P ;
RUIZ, C ;
SAWYER, P ;
TORRES, J ;
HUSSEY, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) :4828-4833
[2]   Time-dependent, x-ray spectral unfolds and brightness temperatures for intense Li+ ion beam-driven hohlraums [J].
Fehl, DL ;
Chandler, GA ;
Biggs, F ;
Dukart, RJ ;
Moats, AR ;
Leeper, RJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01) :843-846
[3]  
KELTNER NR, COMMUNICATION
[4]   Z pinches as intense x-ray sources for high-energy density physics applications [J].
Matzen, MK .
PHYSICS OF PLASMAS, 1997, 4 (05) :1519-1527
[5]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176
[6]  
MIX LP, 1981, AM I PHYSICS C P, V75, P25
[7]  
NATRELLA MG, 1991, EXPT STAT HDB
[8]   Tungsten wire-array Z-pinch experiments at 200 TW and 2 MJ [J].
Spielman, RB ;
Deeney, C ;
Chandler, GA ;
Douglas, MR ;
Fehl, DL ;
Matzen, MK ;
McDaniel, DH ;
Nash, TJ ;
Porter, JL ;
Sanford, TWL ;
Seamen, JF ;
Stygar, WA ;
Struve, KW ;
Breeze, SP ;
McGurn, JS ;
Torres, JA ;
Zagar, DM ;
Gilliland, TL ;
Jobe, DO ;
McKenney, JL ;
Mock, RC ;
Vargas, M ;
Wagoner, T ;
Peterson, DL .
PHYSICS OF PLASMAS, 1998, 5 (05) :2105-2111
[9]  
TACHER P, COMMUNICATION
[10]   THEORY OF ISOPERIBOL CALORIMETRY FOR LASER POWER AND ENERGY MEASUREMENTS [J].
WEST, ED ;
CHURNEY, KL .
JOURNAL OF APPLIED PHYSICS, 1970, 41 (06) :2705-&