Mapping of atrial activation with a noncontact, multielectrode catheter in dogs

被引:92
作者
Kadish, A
Hauck, J
Pederson, B
Beatty, G
Gornick, C
机构
[1] Northwestern Univ, Sch Med, Dept Internal Med, Div Cardiol, Chicago, IL USA
[2] Northwestern Univ, Sch Med, Feinberg Cardiovasc Res Inst, Chicago, IL USA
[3] Endocardial Solut, Minneapolis, MN USA
[4] Univ Minnesota, Sch Med, Minneapolis, MN 55455 USA
[5] Minneapolis VA Hosp, Minneapolis, MN USA
关键词
atrial flutter; fibrillation; mapping;
D O I
10.1161/01.CIR.99.14.1906
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Endocardial mapping of sustained arrhythmias has traditionally been performed with a roving diagnostic catheter. Although this approach is adequate for many tachyarrhythmias, it has limitations, The purpose of-this study was to evaluate a novel noncontact mapping system for assessing atrial tachyarrhythmias. Methods and Results-The mapping system consists of a 9F multielectrode-array balloon catheter that has 64 active electrodes and ring electrodes for emitting a locator signal. The locator signal was used to construct a 3-dimensional right atrial map; it was independently validated and was highly accurate. Virtual electrograms were calculated at 3360 endocardial sites in the right atrium. We evaluated right atrial activation by positioning the balloon catheter in the mid right atrium via a femoral venous approach. Experiments were performed on 12 normal mongrel dogs. The mean correlation coefficient between contact and virtual electrograms was 0.80+/-0.12 during sinus rhythm. Fifty episodes of atrial flutter induced in Il animals were evaluated. In the majority of experiments, complete or almost complete reentrant circuits could be identified within the right atrium. Mean correlation coefficient between virtual and contact electrograms was 0.85+/-0.17 in atrial flutter. One hundred fifty-six episodes of pacing-induced atrial fibrillation were evaluated in 11 animals. Several distinct patterns of right atrial activation were seen, including single-activation wave fronts and multiple simultaneous-activation wave fronts. Mean correlation coefficient between virtual and contact electrograms during atrial fibrillation was 0.81+/-0.18. The accuracy of electrogram reconstruction was lower at sites >4.0 cm from the balloon center and at sites with a high spatial complexity of electrical activation. Conclusions-This novel noncontact mapping system can evaluate conduction patterns during sinus rhythm, demonstrate reentry during atrial flutter, and describe right atrial activation during atrial fibrillation. The accuracy of electrogram reconstruction was good at sites <4.0 cm from the balloon center, and thus the system has the ability to perform high-resolution multisite mapping of atrial tachyarrhythmias in vivo.
引用
收藏
页码:1906 / 1913
页数:8
相关论文
共 23 条
[1]   THE USE OF CROSS-CORRELATION FUNCTION FOR THE ALIGNMENT OF ECG WAVEFORMS AND REJECTION OF EXTRASYSTOLES [J].
ABBOUD, S ;
SADEH, D .
COMPUTERS AND BIOMEDICAL RESEARCH, 1984, 17 (03) :258-266
[2]  
Adler Stuart, 1996, Journal of the American College of Cardiology, V27, p75A
[3]   INTRA-ATRIAL REENTRY AS A MECHANISM FOR ATRIAL-FLUTTER INDUCED BY ACETYLCHOLINE AND RAPID PACING IN THE DOG [J].
ALLESSIE, MA ;
LAMMERS, WJEP ;
BONKE, IM ;
HOLLEN, J .
CIRCULATION, 1984, 70 (01) :123-135
[4]  
BEATTY GE, 1994, CIRCULATION, V90, P280
[5]   Quantitative assessment of the spatial organization of atrial fibrillation in the intact human heart [J].
Botteron, GW ;
Smith, JM .
CIRCULATION, 1996, 93 (03) :513-518
[6]  
BYRNE J, 1997, J PHARMACOL EXP THER, V200, P147
[7]   ATRIAL AND ACCESSORY PATHWAY ACTIVATION DIRECTION IN PATIENTS WITH ORTHODROMIC SUPRAVENTRICULAR TACHYCARDIA - INSIGHTS FROM VECTOR MAPPING [J].
DAMLE, RS ;
CHOE, W ;
KANAAN, NM ;
EHLERT, FA ;
GOLDBERGER, JJ ;
KADISH, AH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (03) :684-692
[8]   Percutaneous multielectrode endocardial mapping during ventricular tachycardia in the swine model [J].
Eldar, M ;
Fitzpatrick, AP ;
Ohad, D ;
Smith, MF ;
Hsu, S ;
Whayne, JG ;
Vered, Z ;
Rotstein, Z ;
Kordis, T ;
Swanson, DK ;
Chin, M ;
Scheinman, MM ;
Lesh, MD ;
Greenspon, AJ .
CIRCULATION, 1996, 94 (05) :1125-1130
[9]   RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF HUMAN TYPE-1 ATRIAL-FLUTTER - IDENTIFICATION OF A CRITICAL ZONE IN THE REENTRANT CIRCUIT BY ENDOCARDIAL MAPPING TECHNIQUES [J].
FELD, GK ;
FLECK, RP ;
CHEN, PS ;
BOYCE, K ;
BAHNSON, TD ;
STEIN, JB ;
CALISI, CM ;
IBARRA, M .
CIRCULATION, 1992, 86 (04) :1233-1240
[10]  
Gepstein L, 1997, CIRCULATION, V95, P1611