Polymer-hydroxyapatite composite versus polymer interference screws in anterior cruciate ligament reconstruction in a large animal model

被引:35
作者
Hunt, John A. [1 ]
Callaghan, Jill T. [1 ]
机构
[1] Univ Liverpool, Sch Clin Sci, UK Ctr Tissue Engn, Liverpool L69 3GA, Merseyside, England
基金
英国医学研究理事会;
关键词
anterior cruciate ligament; bioabsorbable implants; hydroxyapatite-tricalciumphosphate composite; hydroxyapatite-polylactide; medical device;
D O I
10.1007/s00167-008-0528-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of the study was to assess the hard tissue response of a composite hydroxyapatite/poly L-lactic acid (HA/PLLA) interference screw for anterior cruciate ligament (ACL) reconstruction compared to a standard PLLA screw. Twelve skeletally mature rams underwent unilateral ACL reconstruction using an autologous bone-patellar tendon graft. Each animal received either two test HA/PLLA interference screws or two control PLLA interference screws. Animals were sacrificed at 6 and 12 months post-implantation and the operated knees excised. Undecalcified sections of the screw and surrounding tissues were cut from resin embedded samples and stained; sections were approximately parallel to the longitudinal axis of the screws. A quantitative assessment of bone formation between each screw type (PLLA vs. HA/PLLA) and adjacent tissue in both the tibia and femur was undertaken using automated image analysis (KS400, Zeiss, UK). The inflammatory response of each screw type was assessed by histological evaluation. New bone formation along the perimeter of the screw threads was statistically significantly higher with the HA/PLLA than the PLLA alone. The inflammatory response as assessed semi-quantitatively by histologically determining the number of inflammatory cells present in the tissue adjacent to the implant, was higher for PLLA than HA/PLLA. Significantly increased new bone formation and decreased inflammatory cells were observed in vivo with the composite screw in comparison with the standard polymer. A novel HA/PLLA composite biomaterial in the form of an interference screw demonstrated an improved hard-tissue response compared to PLLA in a large animal ACL reconstruction. This study determined the differences in the tissue response between PLLA and a composite material of HA/PLLA. The improved tissue related outcomes observed in vivo, may be of benefit clinically in ACL reconstruction.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 30 条
[1]
Agrawal CM, 1997, J BIOMED MATER RES, V38, P105, DOI 10.1002/(SICI)1097-4636(199722)38:2<105::AID-JBM4>3.0.CO
[2]
2-U
[3]
Orthopaedic applications for PLA-PGA biodegradable polymers [J].
Athanasiou, KA ;
Agrawal, CM ;
Barber, FA ;
Burkhart, SS .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (07) :726-737
[4]
Long-term absorption of poly-L-lactic acid interference screws [J].
Barber, F. Alan ;
Dockery, W. Dee .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (08) :820-826
[5]
Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction [J].
Baums, M. H. ;
Zelle, B. A. ;
Schultz, W. ;
Ernstberger, T. ;
Klinger, H. -M. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (09) :865-868
[7]
Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
[8]
Graft fixation in cruciate ligament reconstruction [J].
Brand, J ;
Weiler, A ;
Caborn, DNM ;
Brown, CH ;
Johnson, DL .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05) :761-774
[9]
Bush-Joseph C A, 1998, Am J Knee Surg, V11, P32
[10]
Ciccone W J 2nd, 2001, J Am Acad Orthop Surg, V9, P280