Determination of teflon thickness with laser speckle .1. Potential for burn depth diagnosis

被引:44
作者
Sadhwani, A
Schomacker, KT
Tearney, GJ
Nishioka, NS
机构
[1] HARVARD UNIV, SCH MED, DEPT DERMATOL, BOSTON, MA 02115 USA
[2] HARVARD UNIV, SCH MED, DEPT MED, BOSTON, MA 02115 USA
[3] MASSACHUSETTS GEN HOSP, MED SERV, BOSTON, MA 02114 USA
关键词
burn diagnosis; laser speckle; tissue phantoms; speckle decorrelation time; Brownian motion;
D O I
10.1364/AO.35.005727
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A quantitative method for determining the depth of burn eschar would aid surgeons in determining whether to excise and subsequently graft a burn wound. We hypothesize that tissue viability could be assessed by an analysis of the spatial modulation of near-field laser speckle by flowing blood. A feasibility study of the technique was performed with two-layer tissue phantoms used to simulate a burn wound. A sheet of polytetrafluoroethylene (PTFE) was used to simulate nonperfused burn eschar, and tissue perfusion within deeper layers was represented by Brownian motion from a scattering solution. A low-power He-Ne laser was focused onto the target, and the resulting speckle image was captured with a CCD camera and stored on a computer for further processing. The diameter of the speckle pattern was found to be directly proportional to the thickness of the overlying layer. These data suggest that the thickness of PTFE can be determined to +/-100-mu m accuracy with 95% confidence and may be suitable for burn depth detection in vivo. (C) 1996 Optical Society of America
引用
收藏
页码:5727 / 5735
页数:9
相关论文
共 33 条
[1]   MULTISPECTRAL IMAGING OF BURN WOUNDS - A NEW CLINICAL INSTRUMENT FOR EVALUATING BURN DEPTH [J].
AFROMOWITZ, MA ;
CALLIS, JB ;
HEIMBACH, DM ;
DESOTO, LA ;
NORTON, MK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (10) :842-850
[2]   CLINICAL-EVALUATION OF BURN INJURIES USING AN OPTICAL REFLECTANCE TECHNIQUE [J].
AFROMOWITZ, MA ;
VANLIEW, GS ;
HEIMBACH, DM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (02) :114-127
[3]   BIO-SPECKLE PHENOMENA AND THEIR APPLICATION TO THE EVALUATION OF BLOOD-FLOW [J].
AIZU, Y ;
ASAKURA, T .
OPTICS AND LASER TECHNOLOGY, 1991, 23 (04) :205-219
[4]   EVALUATION OF BLOOD-FLOW AT OCULAR FUNDUS BY USING LASER SPECKLE [J].
AIZU, Y ;
OGINO, K ;
SUGITA, T ;
YAMAMOTO, T ;
TAKAI, N ;
ASAKURA, T .
APPLIED OPTICS, 1992, 31 (16) :3020-3029
[5]   CUTANEOUS 10MHZ ULTRASOUND B-SCAN ALLOWS THE QUANTITATIVE ASSESSMENT OF BURN DEPTH [J].
BAUER, JA ;
SAUER, T .
BURNS, 1989, 15 (01) :49-51
[6]  
BENNETT J E, 1957, Plast Reconstr Surg (1946), V20, P261, DOI 10.1097/00006534-195710000-00001
[7]  
CANTRELL JH, 1984, J TRAUMA, V24, P64
[8]   A REVIEW OF THE OPTICAL-PROPERTIES OF BIOLOGICAL TISSUES [J].
CHEONG, WF ;
PRAHL, SA ;
WELCH, AJ .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2166-2185
[9]   THERMOGRAPHIC ASSESSMENT OF HAND BURNS [J].
COLE, RP ;
JONES, SG ;
SHAKESPEARE, PG .
BURNS, 1990, 16 (01) :60-63
[10]   A clinical test for differentiating second from third degree burns [J].
Dingwall, JA .
ANNALS OF SURGERY, 1943, 119 :427-429