Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study

被引:113
作者
Deeley, M. A. [1 ]
Chen, A. [2 ]
Datteri, R. [2 ]
Noble, J. H. [2 ]
Cmelak, A. J. [1 ]
Donnelly, E. F. [3 ]
Malcolm, A. W. [1 ]
Moretti, L. [1 ,4 ]
Jaboin, J. [1 ]
Niermann, K. [1 ]
Yang, Eddy S. [1 ]
Yu, David S. [1 ]
Yei, F. [5 ]
Koyama, T. [5 ]
Ding, G. X. [1 ]
Dawant, B. M. [2 ]
机构
[1] Vanderbilt Univ, Dept Radiat Oncol, Nashville, TN USA
[2] Vanderbilt Univ, Dept Elect Engn & Comp Sci, Nashville, TN USA
[3] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN USA
[4] Univ Libre Bruxelles, Dept Radiat Oncol, Inst Jules Bordet, Brussels, Belgium
[5] Vanderbilt Univ, Dept Biostat, Nashville, TN USA
关键词
NONRIGID IMAGE REGISTRATION; RADIATION-THERAPY USE; DEFORMABLE REGISTRATION; ADAPTIVE RADIOTHERAPY; MR-IMAGES; VALIDATION; ALGORITHM; PROPAGATION; DELINEATION; CONTEXT;
D O I
10.1088/0031-9155/56/14/021
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, of 20 patients who underwent therapy for large space-occupying tumors. Performance variability was assessed through three geometric measures: volume, Dice similarity coefficient, and Euclidean distance. In addition, two simulated ground truth segmentations were calculated via the simultaneous truth and performance level estimation algorithm and a novel application of probability maps. The experts and automatic system were found to generate structures of similar volume, though the experts exhibited higher variation with respect to tubular structures. No difference was found between the mean Dice similarity coefficient (DSC) of the automatic and expert delineations as a group at a 5% significance level over all cases and organs. The larger structures of the brainstem and eyes exhibited mean DSC of approximately 0.8-0.9, whereas the tubular chiasm and nerves were lower, approximately 0.4-0.5. Similarly low DSCs have been reported previously without the context of several experts and patient volumes. This study, however, provides evidence that experts are similarly challenged. The average maximum distances (maximum inside, maximum outside) from a simulated ground truth ranged from (-4.3, +5.4) mm for the automatic system to (-3.9, +7.5) mm for the experts considered as a group. Over all the structures in a rank of true positive rates at a 2 mm threshold from the simulated ground truth, the automatic system ranked second of the nine raters. This work underscores the need for large scale studies utilizing statistically robust numbers of patients and experts in evaluating quality of automatic algorithms.
引用
收藏
页码:4557 / 4577
页数:21
相关论文
共 38 条
[1]
An evaluation of four automatic methods of segmenting the subcortical structures in the brain [J].
Babalola, Kolawole Oluwole ;
Patenaude, Brian ;
Aljabar, Paul ;
Schnabel, Julia ;
Kennedy, David ;
Crum, William ;
Smith, Stephen ;
Cootes, Tim ;
Jenkinson, Mark ;
Rueckert, Daniel .
NEUROIMAGE, 2009, 47 (04) :1435-1447
[2]
A comparison of ground truth estimation methods [J].
Biancardi, Alberto M. ;
Jirapatnakul, Artit C. ;
Reeves, Anthony P. .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (03) :295-305
[3]
Atlas-based automatic segmentation of MR images: Validation study on the brainstem in radiotherapy context [J].
Bondiau, PY ;
Malandain, G ;
Chanalet, S ;
Marcy, PY ;
Habrand, JL ;
Fauchon, F ;
Paquis, P ;
Courdi, A ;
Commowick, O ;
Rutten, I ;
Ayache, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (01) :289-298
[4]
BURR DJ, 1981, COMPUT VISION GRAPH, V15, P102, DOI 10.1016/0146-664X(81)90072-1
[5]
CAUDRA MB, 2006, COMPUT METH PROG BIO, V84, P66
[6]
Auto-propagation of contours for adaptive prostate radiation therapy [J].
Chao, Ming ;
Xie, Yaoqin ;
Xing, Lei .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) :4533-4542
[7]
Consistent image registration [J].
Christensen, GE ;
Johnson, HJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (07) :568-582
[8]
Generalized overlap measures for evaluation and validation in medical image analysis [J].
Crum, William R. ;
Camara, Oscar ;
Hill, Derek L. G. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (11) :1451-1461
[9]
Non-rigid image registration: theory and practice [J].
Crum, WR ;
Hartkens, T ;
Hill, DLG .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 :S140-S153
[10]
Atlas-based segmentation of pathological MR brain images using a model of lesion growth [J].
Cuadra, MB ;
Pollo, C ;
Bardera, A ;
Cuisenaire, O ;
Villemure, JG ;
Thiran, JP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (10) :1301-1314