Gold nanoelectrode ensembles for the simultaneous electrochemical detection of ultratrace arsenic, mercury, and copper

被引:310
作者
Jena, Bikash Kumar [1 ]
Raj, C. Retna [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Kharagpur 721302, W Bengal, India
关键词
D O I
10.1021/ac071064w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simultaneous electrochemical detection of As(III), Hg(II), and Cu(II) using a highly sensitive platform based on gold nanoelectrode ensembles (GNEEs) is described. GNEEs were grown by colloidal chemical approach on thiol-functionalized sol-gel derived three-dimensional silicate network preassembled on a polycrystalline gold (Au) electrode. GNEEs on the silicate network have been characterized by field emission scanning electron microscopy, X-ray diffraction, diffuse reflectance spectroscopy, and electrochemical measurements. Square wave anodic stripping voltammetry (SWASV) has been used for the detection of As(111) and Hg(H) without any interference from Cu(11) at the potentials of 0.06 and 0.53 V, respectively. The GNEE electrode is highly sensitive, and it shows linear response for As(III) and Hg(II) up to 15 ppb. The detection limit (signal-to-noise ratio = 4) of the GNEE electrode toward As(111) and Hg(H) is 0.02 ppb, which is well below the guideline value given by the World Health Organization (WHO). The potential application of the GNEE electrode for the detection of As(III) in. a real sample collected from the arsenic-contaminated water in 24 North Parganas, West Bengal is demonstrated. The GNEE electrode has been successfully used for the simultaneous detection of As(111), Cu(H), and Hg(H) at sub-part-per-billion level without any interference for the first time. The nanostructured electrode shows individual voltammetzic peaks for As(111), Cu(II), and Hg(H) at 0.06, 0.35, and 0.53 V, respectively. The analytical performance of the GNEE electrode is superior to the existing electrodes.
引用
收藏
页码:4836 / 4844
页数:9
相关论文
共 74 条
[1]  
Abernathy C, 1999, ARSENIC EXPOSURE HLT
[2]  
Agency for Toxic Substances and Disease Registry, 1999, TOX PROF MERC
[3]   Flow injection method for the determination of arsenic(III) at trace levels in alkaline media [J].
Aldstadt, JH ;
Martin, AF .
ANALYST, 1996, 121 (10) :1387-1391
[4]   DETERMINATION OF TRACE MERCURY(II) IN 0.1 M-PERCHLORIC ACID BY DIFFERENTIAL PULSE STRIPPING VOLTAMMETRY AT A ROTATING GOLD DISK ELECTRODE [J].
ANDREWS, RW ;
LAROCHELLE, JH ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1976, 48 (01) :212-214
[5]   ONLINE PHOTOOXIDATION FOR THE DETERMINATION OF ORGANOARSENIC COMPOUNDS BY ATOMIC-ABSORPTION SPECTROMETRY WITH CONTINUOUS ARSINE GENERATION [J].
ATALLAH, RH ;
KALMAN, DA .
TALANTA, 1991, 38 (02) :167-173
[6]  
Bard A. J., 2001, ELECTROCHEMICAL METH, P44
[7]   Seeding of colloidal Au nanoparticle solutions. 2. Improved control of particle size and shape [J].
Brown, KR ;
Walter, DG ;
Natan, MJ .
CHEMISTRY OF MATERIALS, 2000, 12 (02) :306-313
[8]   Determination of various arsenic species by flow injection hydride generation atomic absorption spectrometry:: investigation of the effects of the acid concentration of different reaction media on the generation of arsines [J].
Carrero, P ;
Malavé, A ;
Burguera, JL ;
Burguera, M ;
Rondón, C .
ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) :195-204
[9]   SIMULATION OF EDGE EFFECTS IN ELECTROANALYTICAL EXPERIMENTS BY ORTHOGONAL COLLOCATION .6. CYCLIC VOLTAMMETRY AT ULTRAMICROELECTRODE ENSEMBLES [J].
CASSIDY, J ;
GHOROGHCHIAN, J ;
SARFARAZI, F ;
SMITH, JJ ;
PONS, S .
ELECTROCHIMICA ACTA, 1986, 31 (06) :629-636
[10]   Analysis and speciation of traces of arsenic in environmental food and industrial samples by voltammetry: a review [J].
Cavicchioli, A ;
La-Scalea, MA ;
Gutz, IGR .
ELECTROANALYSIS, 2004, 16 (09) :697-711