WIMP dark matter detectors above 100 K

被引:7
作者
Spooner, N [1 ]
机构
[1] Univ Sheffield, Dept Phys, Sheffield S3 7RH, S Yorkshire, England
来源
PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS | 1998年 / 307卷 / 1-4期
关键词
D O I
10.1016/S0370-1573(98)00042-8
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Of key motivation in the development of detector strategies in the search for Weakly Interacting Massive Particles (WIMPs) is the need to maximize the information obtainable from the expected elastic recoil events so that these can be distinguished from background interactions and systematic errors can be controlled. Low temperature techniques may provide one route. However, most of the detector technology currently used, and those responsible for the best limits so far, do not involve cryogenic methods but rely on more conventional technology such as scintillators. There is increasing confidence that these techniques can reach the required sensitivity and may even provide the first detector with sensitivity to the direction of WIMP recoils. Reviewed here is the status of these techniques and the improvements planned to allow exploration of possible dark matter signal rates below 0.1 kg(-1) d(-1). (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:253 / 261
页数:9
相关论文
共 40 条
[1]  
BELLI P, 1992, NUOVO CIMENTO C, V15, P475
[2]  
Belli P, 1996, NUCL PHYS B, P60
[3]  
BELLI P, 1997, P TAUP97 7 11 SEPT G
[4]   New limits on WIMP search with large-mass low-radioactivity NaI(Tl) set-up at Gran Sasso [J].
Bernabei, R ;
Belli, P ;
Landoni, V ;
Montecchia, F ;
DiNicolantonio, W ;
Incicchitti, A ;
Prosperi, D ;
Bacci, C ;
Dai, CJ ;
Ding, LK ;
Kuang, HH ;
Ma, JM ;
Angelone, M ;
Batistoni, P ;
Pillon, M .
PHYSICS LETTERS B, 1996, 389 (04) :757-766
[5]   Improved limits on WIMP-F-19 elastic scattering and first limit on the 2EC2 nu Ca-40 decay by using a low radioactive CaF2(Eu) scintillator [J].
Bernabei, R ;
Belli, P ;
Montecchia, F ;
Incicchitti, A ;
DiNicolantonio, W ;
Prosperi, D ;
Bacci, C ;
Dai, CJ ;
Ding, LK ;
Kuang, HH ;
Ma, JM ;
Yao, ZG .
ASTROPARTICLE PHYSICS, 1997, 7 (1-2) :73-76
[6]  
BLAIR IM, 1995, P 2 WORKSH DARK SID, P128
[7]   Detection of neutron-induced nuclear recoils in a low-pressure gaseous detector for particle dark matter searches [J].
Buckland, KN ;
Lehner, MJ ;
Masek, GE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) :6-13
[8]  
COLLAR JJ, 1997, P INT C ID DARK MATT, P563
[9]   LIQUID XENON AS A DARK-MATTER DETECTOR - PROSPECTS FOR NUCLEAR RECOIL DISCRIMINATION BY PHOTON TIMING [J].
DAVIES, GJ ;
DAVIES, JD ;
LEWIN, JD ;
SMITH, PF ;
JONES, WG .
PHYSICS LETTERS B, 1994, 320 (3-4) :395-399
[10]   ESTIMATION OF ABSOLUTE PHOTON YIELDS IN LIQUID ARGON AND XENON FOR RELATIVISTIC (1 MEV) ELECTRONS [J].
DOKE, T ;
MASUDA, K ;
SHIBAMURA, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (03) :617-620