Polymer coatings for stents - Can we judge a stent by its cover?

被引:26
作者
Fischell, TA
机构
关键词
editorials; stents; biocompatibility; polymers;
D O I
10.1161/01.CIR.94.7.1494
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1494 / 1495
页数:2
相关论文
共 14 条
  • [1] BIOCOMPATIBILITY OF POLYMER-COATED OVERSIZED METALLIC STENTS IMPLANTED IN NORMAL PORCINE CORONARY-ARTERIES
    DESCHEERDER, IK
    WILCZEK, KL
    VERBEKEN, EV
    VANDORPE, J
    LAN, PN
    SCHACHT, E
    DEGEEST, H
    PIESSENS, J
    [J]. ATHEROSCLEROSIS, 1995, 114 (01) : 105 - 114
  • [2] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [3] Folts John D., 1996, Journal of the American College of Cardiology, V27, p86A
  • [4] HARDHAMMAR PA, 1996, CIRCULATION, V93, P426
  • [5] Pure beta-particle-emitting stents inhibit neointima formation in rabbits
    Hehrlein, C
    Stintz, M
    Kinscherf, R
    Schlosser, K
    Huttel, E
    Friedrich, L
    Fehsenfeld, P
    Kubler, W
    [J]. CIRCULATION, 1996, 93 (04) : 641 - 645
  • [6] POLYMERIC STENTING IN THE PORCINE CORONARY-ARTERY MODEL - DIFFERENTIAL OUTCOME OF EXOGENOUS FIBRIN SLEEVES VERSUS POLYURETHANE-COATED STENTS
    HOLMES, DR
    CAMRUD, AR
    JORGENSON, MA
    EDWARDS, WD
    SCHWARTZ, RS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (02) : 525 - 531
  • [7] Three-year follow-up after implantation of metallic coronary-artery stents
    Kimura, T
    Yokoi, H
    Nakagawa, Y
    Tamura, T
    Kaburagi, S
    Sawada, Y
    Sato, Y
    Yokoi, H
    Hamasaki, N
    Nosaka, H
    Nobuyoshi, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) : 561 - 566
  • [8] Inhibition of neointimal proliferation with low-dose irradiation from a beta-particle-emitting stent
    Laird, JR
    Carter, AJ
    Kufs, WM
    Hoopes, TG
    Farb, A
    Nott, SH
    Fischell, RE
    Fischell, DR
    Virmani, R
    Fischell, TA
    [J]. CIRCULATION, 1996, 93 (03) : 529 - 536
  • [9] Heparin-coated Palmaz-Schatz stents in human coronary arteries - Early outcome of the Benestent-II pilot study
    Serruys, PW
    Emanuelsson, H
    vanderGiessen, W
    Lunn, AC
    Kiemeney, F
    Macaya, C
    Rutsch, W
    Heyndrickx, G
    Suryapranata, H
    Legrand, V
    Goy, JJ
    Materne, P
    Bonnier, H
    Morice, MC
    Fajadet, J
    Belardi, J
    Colombo, A
    Garcia, E
    Ruygrok, P
    deJaegere, P
    Morel, MA
    [J]. CIRCULATION, 1996, 93 (03) : 412 - 422
  • [10] A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    SERRUYS, PW
    DEJAEGERE, P
    KIEMENEIJ, F
    MACAYA, C
    RUTSCH, W
    HEYNDRICKX, G
    EMANUELSSON, H
    MARCO, J
    LEGRAND, V
    MATERNE, P
    BELARDI, J
    SIGWART, U
    COLOMBO, A
    GOY, JJ
    VANDENHEUVEL, P
    DELCAN, J
    MOREL, MA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 489 - 495