Day-to-day variability of global left ventricular functional and perfusional measurements by quantitative gated SPECT using Tc-99m tetrofosmin in patients with heart failure due to coronary artery disease

被引:18
作者
De Winter, O
De Bondt, P
Van De Wiele, C
De Backer, G
Dierckx, RA
De Sutter, J
机构
[1] State Univ Ghent Hosp, Div Nucl Med, B-9000 Ghent, Belgium
[2] State Univ Ghent Hosp, Cardiac Rehabil Ctr, B-9000 Ghent, Belgium
[3] State Univ Ghent Hosp, Dept Cardiol, B-9000 Ghent, Belgium
关键词
myocardial gated single photon emission computed tomography; coronary artery disease; left ventricular ejection fraction; heart failure;
D O I
10.1016/j.nuclcard.2003.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Although myocardial gated single photon emission computed tomography (SPECT) is routinely used for functional measurements in patients with coronary artery disease (CAD) and heart failure, day-to-day variability of left ventricular ejection fraction (LVEF), left ventricular (LV) volumes, and global perfusion scoring has not yet been investigated. Methods and Results. In 20 consecutive patients with CAD and an LVEF lower than 40% who routinely underwent a resting tetrofosmin gated SPECT study, we performed an additional gated SPECT study at rest 1 to 5 days later under the same circumstances. LV volumes and LVEF were calculated from the gated SPECT data by commercially available software (QGS). Myocardial perfusion was scored visually by use of a 20-segment, 5-point scoring method. For global LV function and perfusion, agreement between data was investigated by use of Bland-Altman plotting. The 95% limits of agreement found by Bland-Altman analysis were -0.9% +/- 6.0% for LVEF, 3 +/- 20 mL for LV end-diastolic volume, and 4 +/- 20 mL for LV end-systolic volume. Conclusion. In CAD patients with an LVEF lower than 40%, day-to-day variability of measurements of global myocardial function and perfusion is quite similar to interobserver and intraobserver variability. Day-to-day variability of global LV functional parameters obtained by gated cardiac SPECT is fairly small, which indicates that myocardial gated SPECT can be used in daily clinical practice to determine changes in global LV function and perfusion over time in patients with diminished LV function.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 24 条
  • [1] Noninvasive assessment of left ventricular remodeling: Concepts, techniques, and implications for clinical trials
    Anand, IS
    Florea, VG
    Solomon, SD
    Konstam, MA
    Udelson, JE
    [J]. JOURNAL OF CARDIAC FAILURE, 2002, 8 (06) : S452 - S464
  • [2] Left ventricular function: Correlation of quantitative gated SPECT and MR imaging over a wide range of values
    Bavelaar-Croon, CDL
    Kayser, HWM
    van der Wall, EE
    de Roos, A
    Dibbets-Schneider, P
    Pauwels, EKJ
    Germano, G
    Atsma, DE
    [J]. RADIOLOGY, 2000, 217 (02) : 572 - 575
  • [3] Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance
    Bellenger, NG
    Davies, LC
    Francis, JM
    Coats, AJS
    Pennell, DJ
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) : 271 - 278
  • [4] Comparison of post-stress ejection fraction and relative left ventricular volumes by automatic analysis of gated myocardial perfusion single-photon emission computed tomography acquired in the supine and prone positions
    Berman, D
    Germano, G
    Lewin, H
    Kang, XP
    Kavanagh, PB
    Tapnio, P
    Harris, M
    Friedman, J
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (01) : 40 - 47
  • [5] Berman DS, 1999, CLINICAL GATED CARDIAC SPECT, P147
  • [6] SEPARATE ACQUISITION REST THALLIUM-201/STRESS TC-99M SESTAMIBI DUAL-ISOTOPE MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - A CLINICAL VALIDATION-STUDY
    BERMAN, DS
    KIAT, H
    FRIEDMAN, JD
    WANG, FP
    VANTRAIN, K
    MATZER, L
    MADDAHI, J
    GERMANO, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) : 1455 - 1464
  • [7] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [8] Accuracy of the automated assessment of left ventricular function with gated perfusion SPECT in the presence of perfusion defects and left ventricular dysfunction: Correlation with equilibrium radionuclide ventriculography and echocardiography
    Chua, T
    Yin, LC
    Thiang, TH
    Choo, TB
    Ping, DZ
    Leng, LY
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (04) : 301 - 311
  • [9] GERMANO G, 1995, J NUCL MED, V36, P2138
  • [10] GERMANO G, 1999, CLIN GATED CARDIAC S, P138