Definitive method certification of clinical analytes in lyophilized human serum: NIST standard reference material (SRM) 909b

被引:22
作者
Phinney, CS [1 ]
Murphy, KE [1 ]
Welch, MJ [1 ]
Ellerbe, PM [1 ]
Long, SE [1 ]
Pratt, KW [1 ]
Schiller, SB [1 ]
Sniegoski, LT [1 ]
Rearick, MS [1 ]
Vetter, TW [1 ]
Vocke, RD [1 ]
机构
[1] Natl Inst Stand & Technol, Div Analyt Chem, Gaithersburg, MD 20899 USA
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1998年 / 361卷 / 02期
关键词
D O I
10.1007/s002160050837
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The National Institute of Standards and Technology (NIST) has developed several Standard Reference Materials (SRMs) based on human serum. NIST SRM 909b, Human Serum, is a lyophilized human serum material with concentrations for seven organic and six inorganic analytes at two levels certified solely by definitive methods (DMs). This material provides the vehicle by which high precision, high accuracy measurements made with DMs at NIST can be transferred through the measurement hierarchy to other laboratories. Isotope dilution gas chromatographic-mass spectrometric (GC-IDMS) methods were applied to measure cholesterol, creatinine, glucose, urea, uric acid, triglycerides, and total glycerides. Thermal ionization isotope dilution mass spectrometry (TI-IDMS) was used for determination of lithium, magnesium, potassium, calcium, and chloride. In addition, chloride was determined by coulometry. providing a comparison between two DMs. Sodium, which lacks a stable isotope that would permit isotope dilution mass spectrometric (IDMS) measurement, was determined by gravimetry. SRM 909b includes certified values for total glycerides and triglycerides, which were not certified in the previous lot of this material (SRM 909a). Improvement in uniformity of vial fill weight in the production of SRM 909b resulted in smaller certified uncertainties over previous freeze-dried serum SRMs. Uncertainties at the 99% level of confidence for relative expanded uncertainty (%) for certification of the organic analytes on a mmol/L/g basis ranged from 0.44% for urea (level II) to 5.04% for glucose (level II). (In-house studies have shown glucose to be a relatively unstable analyte in similar lyophilized serum materials, degrading at about 1%, per year.) Relative expanded uncertainties (99% C.I.) for certification of inorganic analytes on a mmol/L/g basis ranged from 0.25% for chloride (level I) to 0.49% for magnesium (level II).
引用
收藏
页码:71 / 80
页数:10
相关论文
共 30 条
[1]   ISOTOPE-DILUTION MASS-SPECTROMETRY AND THE NATIONAL REFERENCE SYSTEM [J].
BOWERS, GN ;
FASSETT, JD ;
WHITE, E .
ANALYTICAL CHEMISTRY, 1993, 65 (12) :R475-R479
[2]  
CALI JP, 1977, CLIN CHEM, V23, P1943
[3]   ABSOLUTE ISOTOPIC ABUNDANCE RATIOS AND ATOMIC WEIGHT OF MAGNESIUM [J].
CATANZAR.EJ ;
MURPHY, TJ ;
GARNER, EL ;
SHIELDS, WR .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1966, A 70 (06) :453-+
[4]  
COHEN A, 1980, CLIN CHEM, V26, P854
[5]  
COHEN A, 1986, J LABEL COMP RADIOPH, V24, P587
[6]  
De Bievre P., 1994, TRACE ELEMENT ANAL B, P169
[7]   COMPUTING FACTORS FOR EXACT 2-SIDED TOLERANCE LIMITS FOR A NORMAL-DISTRIBUTION [J].
EBERHARDT, KR ;
MEE, RW ;
REEVE, CP .
COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 1989, 18 (01) :397-413
[8]   DETERMINATION OF SERUM URIC-ACID BY ISOTOPE-DILUTION MASS-SPECTROMETRY AS A NEW CANDIDATE DEFINITIVE METHOD [J].
ELLERBE, P ;
COHEN, A ;
WELCH, MJ ;
WHITE, E .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2173-2177
[9]  
ELLERBE P, 1988, CLIN CHEM, V34, P2280
[10]  
ELLERBE P, 1995, CLIN CHEM, V41, P397