Beat averaging alternatives for transmitral Doppler flow velocity images

被引:9
作者
Hall, AF [1 ]
Nudelman, SP [1 ]
Kovacs, SJ [1 ]
机构
[1] Washington Univ, Med Ctr,Sch Med, Barnes Jewish Hosp, Cardiovasc Div,Cardiovasc Biophys Lab, St Louis, MO 63110 USA
关键词
diastolic function; left ventricle; Doppler echocardiography; mathematical models; image processing;
D O I
10.1016/S0301-5629(98)00060-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
To characterize diastolic function from transmitral Doppler data, the image's maximum velocity envelope (MVE) is fit by a model for flow velocity, To reduce the physiologic beat-to-beat variability of best-fit determined model parameters, averaging of multiple cardiac cycles is indicated. To assess variability mathematically, we modeled physiologic noise as a random (normally-distributed) process and evaluated three methods of averaging (1, averaging model parameters from single images; 2, averaging images; and 3, averaging MVEs) using clinical datasets (50 continuous beats from 5 subjects). Method 2 generates a positive bias because low-velocity beats will not contribute to the composite MVE, The difference between Methods 3 and 1 is less than 2.0 E-5 (m/s)(2) for uncorrelated model parameters. Input having 10% beat-to-beat variation yields a bias of <4% for model parameter mean. Hence, Method 1 was, in general, more robust than Method 3. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:971 / 979
页数:9
相关论文
共 13 条
  • [1] FEYNMAN RP, 1965, FEYNMAN LECT PHYSICS, V1
  • [2] INTRAOBSERVER AND INTEROBSERVER REPRODUCIBILITY OF DOPPLER-ASSESSED INDEXES OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN A POPULATION-BASED STUDY (THE FRAMINGHAM HEART-STUDY)
    GALDERISI, M
    BENJAMIN, EJ
    EVANS, JC
    DAGOSTINO, RB
    FULLER, DL
    LEHMAN, B
    WOLF, PA
    LEVY, D
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (15) : 1341 - 1346
  • [3] Evaluation of model-based processing algorithms for averaged transmitral spectral Doppler images
    Hall, AF
    Nudelman, SP
    Kovacs, SJ
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (01) : 55 - 66
  • [4] AUTOMATED-METHOD FOR CHARACTERIZATION OF DIASTOLIC TRANSMITRAL DOPPLER VELOCITY CONTOURS - EARLY RAPID FILLING
    HALL, AF
    KOVACS, SJ
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (02) : 107 - 116
  • [5] HALL AF, 1993, P 15 INT C IEEE EMBS, V1, P385
  • [6] HKOVACS SJ, 1987, AM J PHYS, V252, pH178
  • [7] Miro J, 1992, J Am Soc Echocardiogr, V5, P489
  • [8] Papoulis A., 1991, Communications and signal processing, V3
  • [9] REPRODUCIBILITY OF DOPPLER INDEXES OF LEFT-VENTRICULAR SYSTOLIC AND DIASTOLIC FUNCTION IN PATIENTS WITH SEVERE CHRONIC HEART-FAILURE
    POZZOLI, M
    CAPOMOLLA, S
    COBELLI, F
    TAVAZZI, L
    [J]. EUROPEAN HEART JOURNAL, 1995, 16 (02) : 194 - 200
  • [10] Schiller N B, 1989, J Am Soc Echocardiogr, V2, P358