Blood-flow models of the circle of Willis from magnetic resonance data

被引:105
作者
Cebral, JR [1 ]
Castro, MA
Soto, O
Löhner, R
Alperin, N
机构
[1] George Mason Univ, Sch Computat Sci, Fairfax, VA 22030 USA
[2] Univ Illinois, Dept Radiol, Chicago, IL USA
关键词
circle of Willis; computational fluid dynamics; hemodynamics; magnetic resonance;
D O I
10.1023/B:ENGI.0000007977.02652.02
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Detailed knowledge of the cerebral hemodynamics is important for a variety of clinical applications. Cerebral perfusion depends not only on the status of the diseased vessels but also on the patency of collateral pathways provided by the circle of Willis. Due to the large anatomical and physiologic variability among individuals, realistic patient-specific models can provide new insights into the cerebral hemodynamics. This paper presents an image-based methodology for constructing patient-specific models of the cerebral circulation. This methodology combines anatomical and physiologic imaging techniques with computer simulation technology. The methodology is illustrated with a finite element model constructed from magnetic resonance image data of a normal volunteer. Several of the remaining challenging problems are identified. This work represents a starting point in the development of realistic models that can be applied to the study of cerebrovascular diseases and their treatment.
引用
收藏
页码:369 / 386
页数:18
相关论文
共 44 条
[1]   PUBS: Pulsatility-based segmentation of lumens conducting non-steady flow [J].
Alperin, N ;
Lee, SH .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :934-944
[2]  
[Anonymous], P 14 US NAT C THEOR
[3]  
[Anonymous], 1993, HUMAN NERVOUS SYSTEM
[4]  
Bakker CJG, 1999, JMRI-J MAGN RESON IM, V9, P119, DOI 10.1002/(SICI)1522-2586(199901)9:1<119::AID-JMRI16>3.3.CO
[5]  
2-6
[6]  
BASOMBRIO FG, 2000, P 11 C NUM METH THEI
[7]   Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics [J].
Calamante, F ;
Yim, PJ ;
Cebral, JR .
NEUROIMAGE, 2003, 19 (02) :341-353
[8]  
CAPLAN LR, 1986, STROKE CLIN APPROACH
[9]   Blood flow modeling in carotid arteries with computational fluid dynamics and MR imaging [J].
Cebral, JR ;
Yim, PJ ;
Löhner, R ;
Soto, O ;
Choyke, PL .
ACADEMIC RADIOLOGY, 2002, 9 (11) :1286-1299
[10]   Image-based finite element Modeling of Hemodynamics in stenosed carotid artery [J].
Cebral, JR ;
Löhner, R ;
Soto, O ;
Choyke, PL ;
Yim, PJ .
MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2002, 4683 :297-304