A high-throughput x-ray microtomography system at the Advanced Photon Source

被引:123
作者
Wang, YX
De Carlo, F
Mancini, DC
McNulty, I
Tieman, B
Bresnahan, J
Foster, I
Insley, J
Lane, P
von Laszewski, G
Kesselman, C
Su, MH
Thiebaux, M
机构
[1] Argonne Natl Lab, Div Math & Comp Sci, Argonne, IL 60439 USA
[2] Univ So Calif, Inst Informat Sci, Los Angeles, CA 90089 USA
[3] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
D O I
10.1063/1.1355270
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A third-generation synchrotron radiation source provides enough brilliance to acquire complete tomographic data sets at 100 nm or better resolution in a few minutes. To take advantage of such high-brilliance sources at the Advanced Photon Source, we have constructed a pipelined data acquisition and reconstruction system that combines a fast detector system, high-speed data networks, and massively parallel computers to rapidly acquire the projection data and perform the reconstruction and rendering calculations. With the current setup, a data set can be obtained and reconstructed in tens of minutes. A specialized visualization computer makes rendered three-dimensional (3D) images available to the beamline users minutes after the data acquisition is completed. This system is capable of examining a large number of samples at sub-mum 3D resolution or studying the full 3D structure of a dynamically evolving sample on a 10 min temporal scale. In the near future, we expect to increase the spatial resolution to below 100 nm by using zone-plate x-ray focusing optics and to improve the time resolution by the use of a broadband x-ray monochromator and a faster detector system. (C) 2001 American Institute of Physics.
引用
收藏
页码:2062 / 2068
页数:7
相关论文
共 12 条
[1]  
[Anonymous], 1998, GRID BLUEPRINT NEW C
[2]  
BREUNIG TM, 1991, XRAY MICROSCOPY, V3, P465
[3]  
DREBIN RA, 1988, P 15 ANN C COMP GRAP, P65, DOI DOI 10.1145/54852.378484
[4]   ULTRAHIGH-RESOLUTION X-RAY TOMOGRAPHY [J].
HADDAD, WS ;
MCNULTY, I ;
TREBES, JE ;
ANDERSON, EH ;
LEVESQUE, RA ;
YANG, L .
SCIENCE, 1994, 266 (5188) :1213-1215
[5]  
JOHNSON QC, 1986, MATER RES SOC S P, V69, P203
[6]   NeXus: A common format for the exchange of neutron and synchrotron data [J].
Klosowski, P ;
Koennecke, M ;
Tischler, JZ ;
Osborn, R .
PHYSICA B, 1997, 241 :151-153
[7]  
Lai B, 1996, P SOC PHOTO-OPT INS, V2880, P171, DOI 10.1117/12.250948
[8]   X-ray microtomography as a fast three-dimensional imaging technology using a CCD camera coupled with a CdWO4 single-crystal scintillator [J].
Lee, HR ;
Lai, B ;
Yun, WB ;
Mancini, DC ;
Cai, ZH .
DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 :257-264
[9]  
Lehr J, 1997, OPTIK, V104, P166
[10]   THE DISTRIBUTED LABORATORY - AN INTERACTIVE VISUALIZATION ENVIRONMENT FOR ELECTRON-MICROSCOPY AND 3D IMAGING [J].
MERCURIO, PJ ;
ELVINS, TT ;
YOUNG, SJ ;
COHEN, PS ;
FALL, KR ;
ELLISMAN, MH .
COMMUNICATIONS OF THE ACM, 1992, 35 (06) :54-63