Application of a double-focusing magnetic sector inductively coupled plasma mass spectrometer with laser ablation for the bulk analysis of rare earth elements in rocks fused with Li2B4O7

被引:41
作者
Odegard, M [1 ]
Dundas, SH [1 ]
Flem, B [1 ]
Grimstvedt, A [1 ]
机构
[1] Geol Survey Norway, N-7040 Trondheim, Norway
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1998年 / 362卷 / 05期
关键词
D O I
10.1007/s002160051110
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Results of the use of a double-focusing, magnetic sector inductively coupled plasma mass spectrometer (ICP-MS) with ultraviolet (UV) laser ablation (LA) are presented for the bulk analysis of rare earth elements (REEs) in rocks fused with Li2B4O7. The sample preparation procedure used a sample to flux weight ratio of 1:7, and was identical with a procedure routinely used for X-ray fluorescence (XRF) analyses of major and minor elements in geological materials. Calibration was based on a total of 18 international standard reference materials (SRMs), and Ba was used as an internal standard element for ail REEs. The calibration curves were constructed using a weighted regression model. The use of internal standard, without exception, improved the correlation coefficients significantly. The 3 sigma detection limits were established by a blank sample of SiO2 spiked with Ba, and were in the range from 0.003 mu g g(-1) (Tb-159) to 0.051 mu g g(-1) (Ce-140). The use of a large set of SRMs for calibration gave a good basis for the evaluation of analytical quality, and extensive data for calculated analytical uncertainty are presented. Instrumental precision and the repeatability of the method were studied separately, and no significant difference in these two sets of parameters were found, indicating that the spread of results predominantly was connected to the instrumental measurements. Repeated ablations on the surface of a disk did not influence subsequent measurements with XRF, showing that the fused disks can be stored for future use in XRF and/or LA-ICP-MS analysis.
引用
收藏
页码:477 / 482
页数:6
相关论文
共 26 条
[1]   LASER ABLATION OF SOLIDS FOR ELEMENTAL ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ARROWSMITH, P .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1437-1444
[2]   MINERAL LEUCOSOME TRACE-ELEMENT PARTITIONING IN A PERALUMINOUS MIGMATITE (A LASER ABLATION-ICP-MS STUDY) [J].
BEA, F ;
PEREIRA, MD ;
STROH, A .
CHEMICAL GEOLOGY, 1994, 117 (1-4) :291-312
[3]   INDUCTIVELY COUPLED PLASMA AS AN ION-SOURCE FOR HIGH-RESOLUTION MASS-SPECTROMETRY [J].
BRADSHAW, N ;
HALL, EFH ;
SANDERSON, NE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (08) :801-803
[4]   DIFFERENTIAL VAPORIZATION DURING LASER ABLATION DEPOSITION OF BI-SR-CA-CU-O SUPERCONDUCTING MATERIALS [J].
CHAN, WT ;
MAO, XL ;
RUSSO, RE .
APPLIED SPECTROSCOPY, 1992, 46 (06) :1025-1031
[5]  
CLAISSE F, 1957, NORELCO REP, V4, P95
[6]   LASER SOLID SAMPLING FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
DENOYER, ER ;
FREDEEN, KJ ;
HAGER, JW .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :A445-&
[7]   Analysis of glass by UV laser ablation inductively coupled plasma atomic emission spectrometry .1. Effects of the laser parameters on the amount of ablated material and the temporal behaviour of the signal for different types of laser [J].
DucreuxZappa, M ;
Mermet, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (03) :321-332
[8]   A RAPID METHOD FOR REE AND TRACE-ELEMENT ANALYSIS USING LASER SAMPLING ICP MS ON DIRECT FUSION WHOLE-ROCK GLASSES [J].
FEDOROWICH, JS ;
RICHARDS, JP ;
JAIN, JC ;
KERRICH, R ;
FAN, J .
CHEMICAL GEOLOGY, 1993, 106 (3-4) :229-249
[9]  
FRYER BJ, 1995, CAN MINERAL, V33, P303
[10]   HIGH-RESOLUTION ICP-MS - A NEW CONCEPT FOR ELEMENTAL MASS-SPECTROMETRY [J].
GIESSMANN, U ;
GREB, U .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (4-5) :186-193