Design of flyback echo-planar readout gradients for magnetic resonance spectroscopic imaging

被引:91
作者
Cunningham, CH
Vigneron, DB
Chen, AP
Xu, D
Nelson, SJ
Hurd, RE
Kelley, DA
Pauly, JM
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[3] GE Healthcare Technol, Menlo Pk, CA USA
[4] GE Healthcare Technol, San Francisco, CA USA
关键词
high field; spectroscopic imaging; echo planar; readout trajectory; high resolution;
D O I
10.1002/mrm.20663
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The spatial resolution of conventional magnetic resonance spectroscopic imaging-(MRSI) is typically coarse, mainly due to SNR limitations. The increased signal available with higher field scanners and new array coils now permits higher spatial resolution, but conventional chemical shift imaging (phase encoding) limits the spatial coverage possible in a patient-acceptable acquisition time. The "flyback" echo-planar trajectory is particularly insensitive to errors and provides data that are simple to process. In this study, high-efficiency gradient waveforms for flyback echo-planar MRSI were designed and implemented. Normal volunteer studies at 3 T showed the feasibility of acquiring high spatial resolution with large coverage in a short scan time (2048 voxels in 2.3 min and 4096 voxels in 8.5 min). The trajectories were insensitive to errors in timing and require only a modest (10 to 30%) penalty in SNR relative to conventional phase encoding using the same acquisition time.
引用
收藏
页码:1286 / 1289
页数:4
相关论文
共 9 条
[1]   3-DIMENSIONAL SPECTROSCOPIC IMAGING WITH TIME-VARYING GRADIENTS [J].
ADALSTEINSSON, E ;
IRARRAZABAL, P ;
SPIELMAN, DM ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :461-466
[2]   SPATIAL LOCALIZATION IN NMR-SPECTROSCOPY INVIVO [J].
BOTTOMLEY, PA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 :333-348
[3]  
Bracewell R. N., 1986, FOURIER TRANSFORM IT, V31999
[4]   ECHO-PLANAR IMAGING WITH ASYMMETRIC GRADIENT MODULATION AND INNER-VOLUME EXCITATION [J].
FEINBERG, DA ;
TURNER, R ;
JAKAB, PD ;
VONKIENLIN, M .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :162-169
[5]   SPATIAL-MAPPING OF THE CHEMICAL-SHIFT IN NMR [J].
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1984, 1 (03) :370-386
[6]   Echo planar spectroscopic imaging [J].
Mulkern, RV ;
Panych, LP .
CONCEPTS IN MAGNETIC RESONANCE, 2001, 13 (04) :213-237
[7]   Analysis of volume MRI and MR spectroscopic imaging data for the evaluation of patients with brain tumors [J].
Nelson, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :228-239
[8]   HIGH-SPEED H-1 SPECTROSCOPIC IMAGING IN HUMAN BRAIN BY ECHO-PLANAR SPATIAL-SPECTRAL ENCODING [J].
POSSE, S ;
TEDESCHI, G ;
RISINGER, R ;
OGG, R ;
LEBIHAN, D .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) :34-40
[9]   A FAST SPECTROSCOPIC IMAGING METHOD USING A BLIPPED PHASE ENCODE GRADIENT [J].
WEBB, P ;
SPIELMAN, D ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) :306-315