Error analysis of the rapid lifetime determination method for double-exponential decays and new windowing schemes

被引:136
作者
Sharman, KK
Periasamy, A
Ashworth, H
Demas, JN
Snow, NH
机构
[1] Univ Virginia, Dept Biol, Ctr Cellular Imaging, Charlottesville, VA 22903 USA
[2] Dept Phys, S Orange, NJ 07079 USA
[3] Univ Virginia, Dept Chem, Charlottesville, VA 22904 USA
[4] Seton Hall Univ, Dept Chem, S Orange, NJ 07079 USA
关键词
D O I
10.1021/ac981050d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The rapid lifetime determination method (RLD) is a mathematical technique for extremely rapid evaluations of lifetimes in exponential decays, It has been applied in luminescence microscopy and single-molecule lifetime evaluation. To date, the primary application has been in single-exponential evaluations. We present extensions of the method to double exponentials, Using Monte Carlo simulations, we assess the performance of both the double-exponential decay with known lifetimes and the double-exponential decay with unknown preexponential factors and lifetimes. Precision is evaluated as a function of the noise level (Poisson statistics), the ratios of the lifetimes, the ratios of their preexponential factors, and the fitting window. Optimum measurement conditions are determined. RLD is shown to work well over a wide range of practical experimental conditions. If the lifetimes are known, the preexponential factors can be determined with good precision even at low total counts (10(4)), With unknown preexponential factors and lifetimes, precisions decrease but are still acceptable. A new gating scheme (overlapped gating) is shown to offer improved precision for the case of a single-exponential decay, Theoretical predictions are tested against actual experimental data from a laser-based lifetime instrument.
引用
收藏
页码:947 / 952
页数:6
相关论文
共 7 条
[1]   ERROR ANALYSIS OF THE RAPID LIFETIME DETERMINATION METHOD FOR SINGLE EXPONENTIAL DECAYS WITH A NONZERO BASE-LINE [J].
BALLEW, RM ;
DEMAS, JN .
ANALYTICA CHIMICA ACTA, 1991, 245 (01) :121-127
[2]   AN ERROR ANALYSIS OF THE RAPID LIFETIME DETERMINATION METHOD FOR THE EVALUATION OF SINGLE EXPONENTIAL DECAYS [J].
BALLEW, RM ;
DEMAS, JN .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :30-33
[3]  
DEMAS JN, 1983, EXCITED STATE LIFETI, P83
[4]  
Periasamy A., 1994, Journal of Computer-Assisted Microscopy, V6, P1
[5]   Time-resolved fluorescence lifetime imaging microscopy using a picosecond pulsed tunable dye laser system [J].
Periasamy, A ;
Wodnicki, P ;
Wang, XF ;
Kwon, S ;
Gordon, GW ;
Herman, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (10) :3722-3731
[6]   DETECTION OF HUMAN PAPILLOMAVIRUS TYPE-16/18 DNA IN CERVICOVAGINAL CELLS BY FLUORESCENCE-BASED IN-SITU HYBRIDIZATION AND AUTOMATED IMAGE CYTOMETRY [J].
SIADATPAJOUH, M ;
PERIASAMY, A ;
AYSCUE, AH ;
MOSCICKI, AB ;
PALEFSKY, JM ;
WALTON, L ;
DEMARS, LR ;
POWER, JD ;
HERMAN, B ;
LOCKETT, SJ .
CYTOMETRY, 1994, 15 (03) :245-257
[7]   TRANSIENT DIGITIZER FOR THE DETERMINATION OF MICROSECOND LUMINESCENCE LIFETIMES [J].
WOODS, RJ ;
SCYPINSKI, S ;
LOVE, LJC ;
ASHWORTH, HA .
ANALYTICAL CHEMISTRY, 1984, 56 (08) :1395-1400