A microscope set-up and numerical methods are described which enable the measurement and reconstruction of three-dimensional nanosecond fluorescence lifetime images in every voxel. The frequency domain fluorescence lifetime imaging microscope (FLIM) utilizes phase detection of high-frequency modulated light by homodyne mixing on a microchannel plate image intensifier. The output signal at the image intensifier's phosphor screen is integrated on a charge coupled device camera, A scanning stage is employed to obtain a series of phase-dependent intensity images at equally separated depths in a specimen. The Fourier transform of phase-dependent data gives three-dimensional (3D) images of the Fourier coefficients. These images are deblurred using an Iterative Constrained Tikhonov-Miller (ICTM) algorithm in conjunction with a measured point spread function, The 3D reconstruction of fluorescence lifetimes are calculated from the deblurred images of the Fourier coefficients. An improved spatial and temporal resolution of fluorescence lifetimes was obtained using this approach to the reconstruction of simulated 3D FLIM data. The technique was applied to restore 3D FLIM data of a live cell specimen expressing two green fluorescent protein fusion constructs having distinct fluorescence lifetimes which localized to separate cellular compartments.
引用
收藏
页码:36 / 49
页数:14
相关论文
共 46 条
  • [1] AIKENS RS, 1989, METHOD CELL BIOL, V29, P291
  • [2] Microspectroscopic imaging tracks the intracellular processing of a signal transduction protein: Fluorescent-labeled protein kinase C beta I
    Bastiaens, PIH
    Jovin, TM
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (16) : 8407 - 8412
  • [3] Bertero M, 1996, PROG OPTICS, V36, P129, DOI 10.1016/S0079-6638(08)70314-7
  • [4] Double-pulse fluorescence lifetime measurements
    Buist, AH
    Muller, M
    Gijsbers, EJ
    Brakenhoff, GJ
    Sosnowski, TS
    Norris, TB
    Squier, J
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1997, 186 : 212 - 220
  • [5] Confocal fluorescence microscopy using spectral and lifetime information to simultaneously record four fluorophores with high channel separation
    Carlsson, K
    Liljeborg, A
    [J]. JOURNAL OF MICROSCOPY, 1997, 185 : 37 - 46
  • [6] SUPERRESOLUTION 3-DIMENSIONAL IMAGES OF FLUORESCENCE IN CELLS WITH MINIMAL LIGHT EXPOSURE
    CARRINGTON, WA
    LYNCH, RM
    MOORE, EDW
    ISENBERG, G
    FOGARTY, KE
    FREDRIC, FS
    [J]. SCIENCE, 1995, 268 (5216) : 1483 - 1487
  • [7] Clegg RM, 1996, FLUORESCENCE MICROSCOPY AND FLUORESCENT PROBES, P15
  • [8] CLEGG RM, 1992, P SOC PHOTO-OPT INS, V1640, P448, DOI 10.1117/12.58237
  • [9] THE NUCLEOPLASMIN NUCLEAR LOCATION SEQUENCE IS LARGER AND MORE COMPLEX THAN THAT OF SV40 LARGE T-ANTIGEN
    DINGWALL, C
    ROBBINS, J
    DILWORTH, SM
    ROBERTS, B
    RICHARDSON, WD
    [J]. JOURNAL OF CELL BIOLOGY, 1988, 107 (03) : 841 - 849
  • [10] Fluorescence lifetime imaging by asynchronous pump-probe microscopy
    Dong, CY
    So, PTC
    French, T
    Gratton, E
    [J]. BIOPHYSICAL JOURNAL, 1995, 69 (06) : 2234 - 2242