The balance of the impeller-driver magnet affects the antithrombogenicity in the gyro permanently implantable pump

被引:5
作者
Ichikawa, S
Nishimura, I
Mikami, M
Nonaka, K
Linneweber, J
Kawahito, S
Motomura, T
Ishitoya, H
Glueck, J
Shinohara, T
Nosé, Y
机构
[1] Baylor Coll Med, Michael E DeBakey Dept Surg, Houston, TX 77030 USA
[2] Miwatec Co Ltd, Tokyo, Japan
关键词
antithrombogenicity; biventricular assist device; gyro permanently implantable pump; magnet balance;
D O I
10.1046/j.1525-1594.2002.07120.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Gyro permanently implantable (PI) pump is activated magnetically when a double pivot bearing supported impeller is rotated at predetermined revolutions per minute (rpm). The male bearing shaft of the impeller is supported by the top and bottom female pivot bearing in a loosely mated fashion. The Gyro PI pump's impeller transfers to a floating condition when the rpm is increased. The design objective of the Gyro PI pump is to drive the impeller while maintaining a top contact position to prevent thrombus formation. As a left ventricular assist device (LVAD), the Gyro PI pumps achieved long-term survivals in calves without thrombus formation. However, thrombus formation occurred during a biventricular assist device (BVAD) implantation. Our hypothesis was that the impeller remaining in the bottom contact position during the BVAD experiment caused this thrombus formation. Therefore, a replica of the Gyro PI pump housing was fabricated from a transparent plastic to observe the floating conditions of the impeller. When simulating an LVAD animal experiment, the impeller was at a non-bottom contact position. However, when simulating the BVAD animal experiment, the impeller remained at the bottom contact position. This study shows that the magnet balance affects the antithrombogenicity in a Gyro PI pump.
引用
收藏
页码:927 / 930
页数:4
相关论文
共 5 条
[1]   Evaluation of the wear of the pivot bearing in the Gyro C1E3 pump [J].
Makinouchi, K ;
Nakazawa, T ;
Takami, Y ;
Takatani, S ;
Nose, Y .
ARTIFICIAL ORGANS, 1996, 20 (06) :523-528
[2]   The effect of the impeller-driver magnetic coupling distance on hemolysis in a compact centrifugal pump [J].
Nakazawa, T ;
Makinouchi, K ;
Takami, Y ;
Glueck, J ;
Takatani, S ;
Nose, Y .
ARTIFICIAL ORGANS, 1996, 20 (03) :252-257
[3]  
Nakazawa T, 1997, ARTIF ORGANS, V21, P78
[4]   Development of the Baylor Gyro permanently implantable centrifugal blood pump as a biventricular assist device [J].
Nonaka, K ;
Linneweber, J ;
Ichikawa, S ;
Yoshikawa, T ;
Kawahito, S ;
Mikami, M ;
Motomura, T ;
Ishitoya, H ;
Nishimura, I ;
Oestmann, D ;
Glueck, J ;
Schima, H ;
Wolner, E ;
Shinohara, T ;
Nosé, Y .
ARTIFICIAL ORGANS, 2001, 25 (09) :675-682
[5]   Development of the NEDO implantable ventricular assist device with Gyro centrifugal pump [J].
Yoshikawa, M ;
Nonaka, K ;
Linneweber, J ;
Kawahito, S ;
Ohtsuka, G ;
Nakata, K ;
Takano, T ;
Schulte-Eistrup, S ;
Glueck, J ;
Schima, H ;
Wolner, E ;
Nosé, Y .
ARTIFICIAL ORGANS, 2000, 24 (06) :459-467