A PC program for estimating organ dose and effective dose values in computed tomography

被引:224
作者
Kalender, WA
Schmidt, B
Zankl, M
Schmidt, M
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[2] GSF, Natl Res Ctr Environm & Hlth, Inst Radiat Protect, Neuherberg, Germany
关键词
CT; spiral CT; dose; organ dose; effective dose;
D O I
10.1007/s003300050709
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Dose values in CT are specified by the manufacturers for all CT systems and operating conditions in the phantoms. It is not trivial, however, to derive dose values in patients form this information. Therefore, we have developed a PC-based program which calculates organ dose and effective dose values for arbitrary scan parameters and anatomical ranges. Values for primary radiation are derived from measurements or manufacturer specifications; values for scattered radiation are derived from Monte Carlo calculations tabulated for standard anthropomorphic phantoms. Based on these values, organ doses can be computed by the program for arbitrary scan protocols in conventional and in spiral CT. Effective dose values are also provided, both with ICRP 26 and ICRP 60 tissue-weighting coefficients. Results for several standard CT protocols are presented in tabular form in this paper. In addition, potential for dose reduction is demonstrated, for example, in spiral CT and in quantitative Ct. Providing realistic patient dose estimates for arbitrary CT protocols is relevant both for the physician and the patient, and it si particularly useful for educational and training purposes. The program, called WinDose, is now in use at the Erlangen University hospitals (Germany) as an information tool for radiologists and patients. Further extensions are planned.
引用
收藏
页码:555 / 562
页数:8
相关论文
共 20 条
[1]
[Anonymous], 1990, ICRP PUBL
[2]
[Anonymous], 1982, S885 GSF
[3]
BAUER R, 1998, RADIAT PROT DOSIM, V8, P1
[4]
DUNSTER HJ, 1997, HLTH PHYS, V72, P488
[5]
ICRP, 1975, ICRP PUBL
[6]
ICRP, 1977, ICRP PUBL, V26
[7]
SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[8]
KALENDER WA, 1995, SNRD SOFTWARE PACKAG
[9]
KALENDER WA, 1993, RADIOLOGY, V189, P347
[10]
Effective doses to members of the public from the diagnostic application of ionizing radiation in Germany [J].
Kaul, A ;
Bauer, B ;
Bernhardt, J ;
Nosske, D ;
Veit, R .
EUROPEAN RADIOLOGY, 1997, 7 (07) :1127-1132