An electrochemical label-free and sensitive thrombin aptasensor based on graphene oxide modified pencil graphite electrode

被引:80
作者
Ahour, F. [1 ]
Ahsani, M. K. [1 ]
机构
[1] Urmia Univ, Nanotechnol Res Ctr, Orumiyeh, Iran
关键词
Thrombin; Graphene oxide; Aptamer; Label free; Conformational transformation; SIGNAL-ON; GOLD NANOPARTICLES; PROTEIN-DETECTION; TUMOR-MARKERS; APTAMER; BIOSENSOR; ADENOSINE; ASSAY; ATP; DNA;
D O I
10.1016/j.bios.2016.07.053
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
In this work, we tactfully constructed a novel label-free electrochemical aptasensor for rapid and facile detection of thrombin using graphene oxide (GO) and thrombin binding aptamer (TBA). The strategy relies on the preferential adsorption of single-stranded DNA (ssDNA) to GO over aptamer-target complexes. The TBA-thrombin complex formation was monitored by differential pulse voltammetry (DPV) using the guanine oxidation signal. In the absence of thrombin, the aptamers adsorbed onto the surface of GO leading to a strong background guanine oxidation signal. Conversely, in the presence of thrombin, the conformational transformation of TBA after incubating with the thrombin solution and formation of the aptamer-thrombin complexes which had weak binding ability to GO, leads to the desorption of TBA-thrombin complex from electrode surface and significant oxidation signal decrease. The selectivity of the biosensor was studied using other biological substances. The biosensor's signal was proportional to the thrombin concentration from 0.1 to 10 nM with a detection limit of 0.07 nM. Particularly, the proposed method could be widely applied to the aptamer-based determination of other target analytes. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:764 / 769
页数:6
相关论文
共 43 条
[1]
Rational design of modular allosteric aptamer sensor for label-free protein detection [J].
Bang, Gyeong Sook ;
Cho, Suhyung ;
Lee, Nahum ;
Lee, Bo-Rahm ;
Kim, June-Hyung ;
Kim, Byung-Gee .
BIOSENSORS & BIOELECTRONICS, 2013, 39 (01) :44-50
[2]
Detection of thrombin in human blood by ex-vivo hirudin [J].
Bichler, J ;
Heit, JA ;
Owen, WG .
THROMBOSIS RESEARCH, 1996, 84 (04) :289-294
[3]
On-Chip Synthesis of RNA Aptamer Microarrays for Multiplexed Protein Biosensing with SPR Imaging Measurements [J].
Chen, Yulin ;
Nakamoto, Kohei ;
Niwa, Osamu ;
Corn, Robert M. .
LANGMUIR, 2012, 28 (22) :8281-8285
[4]
Electrochemical aptasensor for detection of copper based on a reagentless signal-on architecture and amplification by gold nanoparticles [J].
Chen, Zhengbo ;
Li, Lidong ;
Mu, Xiaojiao ;
Zhao, Hongtao ;
Guo, Lin .
TALANTA, 2011, 85 (01) :730-735
[5]
Langmuir-Blodgett Assembly of Graphite Oxide Single Layers [J].
Cote, Laura J. ;
Kim, Franklin ;
Huang, Jiaxing .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (03) :1043-1049
[6]
INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[7]
Francois L., 1954, PHYS REV, V34, P722
[8]
The rise of graphene [J].
Geim, A. K. ;
Novoselov, K. S. .
NATURE MATERIALS, 2007, 6 (03) :183-191
[9]
PNA-assembled graphene oxide for sensitive and selective detection of DNA [J].
Guo, Shuang ;
Du, Danxin ;
Tang, Lina ;
Ning, Yong ;
Yao, Qunfeng ;
Zhang, Guo-Jun .
ANALYST, 2013, 138 (11) :3216-3220
[10]
Low background signal platform for the detection of ATP: When a molecular aptamer beacon meets graphene oxide [J].
He, Yue ;
Wang, Zhi-Gang ;
Tang, Hong-Wu ;
Pang, Dai-Wen .
BIOSENSORS & BIOELECTRONICS, 2011, 29 (01) :76-81