Electrophoretic microchip with dual-opposite injection for simultaneous measurements of anions and cations

被引:59
作者
Wang, J [1 ]
Chen, G
Muck, A
Collins, GE
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[2] USN, Res Lab, Washington, DC 20375 USA
关键词
contactless conductivity detection; dual injection; explosive-related ion; microchip capillary electrophoresis; miniaturization; nerve-agent degradation product; simultaneous separation;
D O I
10.1002/elps.200305593
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel dual-injection poly(methylmethacrylate) (PMMA) microchip electrophoretic system has been designed and fabricated for simultaneous measurements of anions and cations using a single channel and detection device. It consists of two sample reservoirs, on both sides of a common separation channel. Anions and cations can be simultaneously electrokinetically injected into both ends of the separation channel. Due to lower electroosmotic flow in polymer channels compared to glass ones, the cations and anions migrate in opposite directions and can be separated from each other and detected using a movable contactless conductivity detector (MCCD) positioned around the center of the separation channel. The effects of the detector position and of the separation voltage on the response and resolution have been studied and optimized for simultaneous determination of six low-energy explosive-related ions, including ammonium, methyl ammonium, sodium, chloride, nitrate, and perchlorate in a single analytical run (of ca. 3 min). Simultaneous detection of nerve-agent degradation products along with explosive-related anions and cations is also demonstrated. The versatile system can also be used for separately measuring anions or cations. The attractive behavior of the dual-opposite injection microchip offers great promise for a wide range of applications, including "total ion analysis" of various samples.
引用
收藏
页码:3728 / 3734
页数:7
相关论文
共 29 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]   An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications [J].
Chabinyc, ML ;
Chiu, DT ;
McDonald, JC ;
Stroock, AD ;
Christian, JF ;
Karger, AM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4491-4498
[3]   Clinical potential of microchip capillary electrophoresis systems [J].
Colyer, CL ;
Tang, T ;
Chiem, N ;
Harrison, DJ .
ELECTROPHORESIS, 1997, 18 (10) :1733-1741
[4]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[5]  
Galloway M, 2002, ELECTROPHORESIS, V23, P3760, DOI 10.1002/1522-2683(200211)23:21<3760::AID-ELPS3760>3.0.CO
[6]  
2-V
[7]   Contact conductivity detection in poly(methyl methacylate)-based microfluidic devices for analysis of mono- and polyanionic molecules [J].
Galloway, M ;
Stryjewski, W ;
Henry, A ;
Ford, SM ;
Llopis, S ;
McCarley, RL ;
Soper, SA .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2407-2415
[8]  
Guijt RM, 2001, ELECTROPHORESIS, V22, P2537, DOI 10.1002/1522-2683(200107)22:12<2537::AID-ELPS2537>3.0.CO
[9]  
2-C
[10]  
Kubán P, 2002, ELECTROPHORESIS, V23, P3725, DOI 10.1002/1522-2683(200211)23:21<3725::AID-ELPS3725>3.0.CO