In this paper a study about the possibility of an early and non-invasive diagnosis of urinary tract cancers with an electronic nose is presented. Measurements of urine headspace were performed by means of an electronic nose based on eight quartz crystal microbalance (QCM) gas sensors coated with different metalloporphyrins. A total of 113 patients affected by various urological pathologies were involved in the experiment, 19 of them were measured twice, before and after the surgical treatment of the cancer. 18 healthy volunteers were used as a reference population. The e-nose data were processed by both principal component analysis (PCA) and discriminant analysis solved by partial least square (PLS-DA). The PLS-DA model related to the data of the healthy and the ills individuals, except the post-surgery samples, shows a complete discrimination between these two groups and a gradual differentiation between prostate and bladder cancer. The application of PCA to the whole data set, shows a migration of the post-surgery class towards the healthy group, suggesting that the headspace of urine samples of patients with the urinary tract cancer is different from that of healthy individuals. These preliminary results confirm a strict correlation between urine headspace and urological pathologies, enhancing the possibility to perform early diagnosis, considered of upmost importance along the medical diagnostic path. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 12 条
[1]   The application of metalloporphyrins as coating material for quartz microbalance-based chemical sensors [J].
Brunink, JAJ ;
DiNatale, C ;
Bungaro, F ;
Davide, FAM ;
DAmico, A ;
Paolesse, R ;
Boschi, T ;
Faccio, M ;
Ferri, G .
ANALYTICA CHIMICA ACTA, 1996, 325 (1-2) :53-64
[2]   Screening for bacterial vaginosis: a novel application of artificial nose technology [J].
Chandiok, S ;
Crawley, BA ;
Oppenheim, BA ;
Chadwick, PR ;
Higgins, S ;
Persaud, KC .
JOURNAL OF CLINICAL PATHOLOGY, 1997, 50 (09) :790-791
[3]   Human skin odor analysis by means of an electronic nose [J].
Di Natale, C ;
Macagnano, A ;
Paolesse, R ;
Tarizzo, E ;
Mantini, A ;
D'Amico, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 65 (1-3) :216-219
[4]   Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors [J].
Di Natale, C ;
Macagnano, A ;
Martinelli, E ;
Paolesse, R ;
D'Arcangelo, G ;
Roscioni, C ;
Finazzi-Agrò, A ;
D'Amico, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) :1209-1218
[5]  
Di Natale C, 1999, PHYSIOL MEAS, V20, P377, DOI 10.1088/0967-3334/20/4/305
[6]   Characterization and design of porphyrins-based broad selectivity chemical sensors for electronic nose applications [J].
Di Natale, C ;
Paolesse, R ;
Macagnano, A ;
Mantini, A ;
Goletti, C ;
D'Amico, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 52 (1-2) :162-168
[7]   The prediction of bacteria type and culture growth phase by an electronic nose with a multi-layer perceptron network [J].
Gardner, JW ;
Craven, M ;
Dow, C ;
Hines, EL .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (01) :120-127
[8]   An intelligent rapid odour recognition model in discrimination of Helicobacter pylori and other gastroesophageal isolates in vitro [J].
Pavlou, AK ;
Magan, N ;
Sharp, D ;
Brown, J ;
Barr, H ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (7-8) :333-342
[9]   Use of an electronic nose system for diagnoses of urinary tract infections [J].
Pavlou, AK ;
Magan, N ;
McNulty, C ;
Jones, JM ;
Sharp, D ;
Brown, J ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (10) :893-899
[10]   VERWENDUNG VON SCHWINGQUARZEN ZUR WAGUNG DUNNER SCHICHTEN UND ZUR MIKROWAGUNG [J].
SAUERBREY, G .
ZEITSCHRIFT FUR PHYSIK, 1959, 155 (02) :206-222