Magnetic-controlled non-competitive enzyme-linked voltammetric immunoassay for carcinoembryonic antigen

被引:16
作者
Fu, Xiao-Hong [1 ]
机构
[1] Yibin Univ, Sch Chem & Chem Engn, Yibin 644000, Peoples R China
关键词
carcinoembryonic antigen; magnetic nanoparticles; voltammetric immunosensor;
D O I
10.1016/j.bej.2007.09.011
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A new flow-through voltammetric immunoassay protocol based on a novel transparent immunoaffinity reactor for the detection of carcinoembryonic antigen (CEA) was proposed. To construct such an affinity reactor, the reactor was initially fabricated by means of immobilization HRP-labeled anti-CEA antibody (H RP-anti-CEA)-functionalized magnetic CoFe2O4 nanoparticles (bionanoparticles) on a home-made carbon paste electrode (CPE) with an external magnet. With a non-competitive immunoassay format, the as-prepared bionanoparticles were incubated with the analyte CEA, and the formed antigen-antibody complex inhibited partly the active center of the immobilized HRP, which decreased the HRP towards H2O2 reduction. Under optimized conditions, the decrease in current response was proportional to the CEA concentration in the range of 1.5-60 ng/ml with a detection limit of 0.5 ng/ml (at 3 delta). The flow-injection immunoassay system could automatically control the incubation, washing and measurement steps with acceptable reproducibility and good stability. Moreover, the proposed immunosensors were used to analyze CEA in human serum specimens. Analytical results of clinical samples show the developed immunosensor has a promising alternative approach for detecting CEA in the clinical diagnosis. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 29 条
[1]   Development of a non-competitive immunoassay for monitoring DDT, its metabolites and analogues in water samples [J].
Anfossi, L ;
Giraudi, G ;
Tozzi, C ;
Giovannoli, C ;
Baggiani, C ;
Vanni, A .
ANALYTICA CHIMICA ACTA, 2004, 506 (01) :87-95
[2]   Development of a non-competitive immunoassay for cortisol and its application to the analysis of saliva [J].
Anfossi, L ;
Tozzi, C ;
Giovannoli, C ;
Baggiani, C ;
Giraudi, G .
ANALYTICA CHIMICA ACTA, 2002, 468 (02) :315-321
[3]  
*BIOCH INC, BC1011 BIOCH INC
[4]  
CHU TM, 1972, CLIN CHEM, V18, P918
[5]   Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen [J].
Dai, Z ;
Yan, F ;
Hua, Y ;
Hu, XY ;
Ju, HX .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 287 (1-2) :13-20
[6]   Langmuir and langmuir-blodgett films of polyfluorenes and their use in polymer light-emitting diodes [J].
Ferreira, Marystela ;
Olivati, Clarissa A. ;
Machado, Angelita M. ;
Assaka, Andressa M. ;
Giacometti, Jose A. ;
Akcelrud, Leni ;
Oliveira, Osvaldo N., Jr. .
JOURNAL OF POLYMER RESEARCH, 2007, 14 (01) :39-44
[7]   Electrode passivation caused by polymerization of different phenolic compounds [J].
Ferreira, Marystela ;
Varela, Hamilton ;
Torresi, Roberto M. ;
Tremiliosi-Filho, Germano .
ELECTROCHIMICA ACTA, 2006, 52 (02) :434-442
[8]   Self-aggregation and phase separation of a styryl dye in monolayer at the liquid-air interface and in Langmuir-Blodgett films [J].
Gambinossi, F ;
Baglioni, P ;
Caminati, G .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2004, 6 (07) :1587-1591
[9]   Spectroscopic properties of Langmuir-Blodgett films containing a potential-sensitive dye [J].
Gambinossi, F ;
Mannini, M ;
Baglioni, P ;
Caminati, G .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2003, 23 (6-8) :897-902
[10]  
*I IOST LTD, EK38 I ISOT LTD