Molded continuous poly(styrene-co-divinylbenzene) rod as a separation medium for the very fast separation of polymers - Comparison of the chromatographic properties of the monolithic rod with columns packed with porous and non-porous beads in high-performance liquid chromatography of polystyrenes

被引:105
作者
Petro, M [1 ]
Svec, F [1 ]
Frechet, JMJ [1 ]
机构
[1] CORNELL UNIV,DEPT CHEM,BAKER LAB,ITHACA,NY 14853
关键词
poly(styrene-co-divinylbenzene); polymers; polystyrenes; monolithic column;
D O I
10.1016/S0021-9673(96)00510-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gradient elution separations of polystyrene standards in a monolithic molded 50x8 mm I.D. poly(styrene-co-divinylbenzene) rod column and in 50x8 mm I.D. and 30x4.1 mm I.D. columns packed with porous and non-porous poly(styrene-co-divinylbenzene) beads has been carried out. All of these separation media differ in shape and porosity. Excellent separations of eight polystyrene standards were achieved with both the molded monolithic rod and porous beads at moderate flow-rates. However, the monolithic medium proved to be superior for high-speed separations using very steep gradients at a flow-rate of 20 ml/min. Three polystyrene standards were separated in the rod column within 4 s. The separation in the column packed with non-porous beads was poor at flow-rates of 2-8 ml/min, while higher flow-rates led to an unacceptably high back pressure.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 32 条
  • [1] FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY
    AFEYAN, NB
    GORDON, NF
    MAZSAROFF, I
    VARADY, L
    FULTON, SP
    YANG, YB
    REGNIER, FE
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01): : 1 - 29
  • [2] BARTH HG, 1994, ANAL CHEM, V66, pR595, DOI 10.1021/ac00084a022
  • [3] HIGH-TEMPERATURE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF A SYNTHETIC COPOLYMER ON A NONPOROUS SUPPORT
    BULLOCK, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (02) : 415 - 423
  • [4] NONPOROUS SILICA SUPPORTS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    COLWELL, LF
    HARTWICK, RA
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (12): : 2721 - 2744
  • [5] DESIGN AND PREPARATION OF NOVEL PARTICULATE AND CONTINUOUS POLYMERIC MACROPOROUS MEDIA FOR THE SEPARATION OF BIOLOGICAL AND SYNTHETIC MOLECULES
    FRECHET, JMJ
    [J]. MAKROMOLEKULARE CHEMIE-MACROMOLECULAR SYMPOSIA, 1993, 70-1 : 289 - 301
  • [6] EFFECT OF INTRAPARTICLE CONVECTION ON THE CHROMATOGRAPHY OF BIOMACROMOLECULES
    FREY, DD
    SCHWEINHEIM, E
    HORVATH, C
    [J]. BIOTECHNOLOGY PROGRESS, 1993, 9 (03) : 273 - 284
  • [7] GALIA M, 1994, J POLYM SCI POL CHEM, V22, P2169
  • [8] Glockner G., 1991, GRADIENT HPLC COPOLY, P45
  • [9] GOODING KM, 1990, HPLC BIOL MOL
  • [10] REVERSED-PHASE CHROMATOGRAPHY OF PROTEINS AND PEPTIDES ON COMPRESSED CONTINUOUS BEDS
    HJERTEN, S
    NAKAZATO, K
    MOHAMMAD, J
    EAKER, D