Quality assurance for the Leksell gamma unit: Considering magnetic resonance image-distortion and delineation failure in the targeting of the internal auditory canal

被引:29
作者
Ertl, A [1 ]
Saringer, W
Heimberger, K
Kindl, P
机构
[1] Univ Vienna, Dept Neurosurg, A-1010 Vienna, Austria
[2] Univ Vienna, Dept Radiol, A-1010 Vienna, Austria
[3] Graz Tech Univ, Phys Tech Inst, A-8010 Graz, Austria
关键词
stereotactic radiosurgery; localization; MR distortion; quality assurance;
D O I
10.1118/1.598499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our aim in this study was to distinguish quantitatively between the localization accuracy of a commercially available stereotactic fixation device as claimed by the manufacturer and the target accuracy as measured by a user, applying neuroradiologic imaging in Gamma Knife planning and phantom irradiation. Missing the target is the most serious possible failure in Gamma Knife and Linac therapy. To reduce this risk, we developed a quality control algorithm and designed a phantom. To evaluate the accuracy of the targeting procedure with a Leksell Gamma unit, and to experience the possible errors in all procedural steps, irradiations of phantoms were performed, using the so-called "unknown" targeting method. Accuracy is defined by the extent of spatial deviation of the irradiated target from the calculated target. Digital imaging was used for therapy planning. GafChromic films, which had been irradiated while affixed to a specially developed phantom, were used for measuring the precision of the radiation unit. A series of MR images (in two plains: transverse and coronal) was acquired sequentially to image the three-dimensional (3-D) volume of the phantom. The results obtained for isocentric accuracy of the Leksell Gamma unit, model B, were in good agreement to the calculated position. The observed spatial deviations between calculated and irradiated targets is less than 1 mm. The newly designed phantom and quality control algorithm are useful in quality assurance measurements of stereotactic radiation therapy. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00802-0].
引用
收藏
页码:166 / 170
页数:5
相关论文
共 32 条
[1]  
[Anonymous], REV MAGN RESON MED
[2]  
Atlas SW., 2009, Magnetic resonance imaging of the brain and spine
[3]   MR ARTIFACTS - A REVIEW [J].
BELLON, EM ;
HAACKE, EM ;
COLEMAN, PE ;
SACCO, DC ;
STEIGER, DA ;
GANGAROSA, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1271-1281
[4]   CHEMICAL-SHIFT IMAGING - A REVIEW [J].
BRATEMAN, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (05) :971-980
[5]  
CHU RDH, 1990, RADIAT PHYS CHEM, V35, P767
[6]  
DANIELS DL, 1986, AM J NEURORADIOL, V7, P249
[7]  
DEPOTTERP, 1995, MRI EYE ORBIT
[8]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[9]  
Hartmann G, 1995, QUALITY ASSURANCE PR
[10]   A SPIN-ECHO CHEMICAL-SHIFT MR IMAGING TECHNIQUE [J].
JOSEPH, PM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :651-658