Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants

被引:25
作者
Howling, GI
Barnett, PI
Tipper, JL
Stone, MH
Fisher, J
Ingham, E
机构
[1] Univ Leeds, Div Microbiol, Old Med Sch, Leeds LS2 9NL, W Yorkshire, England
[2] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[3] Gen Infirm, Dept Orthopaed Surg, Leeds LS1 3EX, W Yorkshire, England
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2001年 / 58卷 / 04期
关键词
UHMWPE; total joint arthroplasty; hip; knee; wear debris;
D O I
10.1002/jbm.1036.abs
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
This study isolated and characterized UHMWPE particles from 3 explant groups: early Charnley hip failures (ECE; < 10 years), late Charnley hip failures (LCE; > 10 years) and early knee failures (EKE; < 10 years). Debris isolated from the 3 groups had percentage particle number and percentage volumetric concentration distributions that were not significantly different. The greatest number of particles were found in the 0.1-0.5 mum size range and 19-20.6% of the volumetric concentration was below 1 mum in size in all groups. However, there were significant differences in the total volumetric concentration of debris isolated per g of tissue. LCE had significantly higher volumes of debris than ECE and EKE, there was no significant difference in the volume of debris from the EKE and ECE, The mean aspect ratio and mean irregularity ratio of the LCE group were also significantly higher than the ECE and EKE, suggesting that different wear mechanisms were occurring in the late Charnley group compared to the early Charnley and knee groups. These results also suggest that early knees, with normal surface wear, may have similar wear mechanisms to early Charnley hips and indicate that similar volumes of biologically active micrometer and sub-micrometer UHMWPE particles were produced, This may have important implications in the longer-term outcome of total knee arthroplasties, because it indicates a similar potential for osteolysis induced by wear debris. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 24 条
[1]
BELL J, 2000, T 6 WORLD BIOM C, V3, P508
[2]
Besong AA, 1997, BIO-MED MATER ENG, V7, P59
[3]
BESONG AA, 1974, T INT C KNEE REP, V2024, P70
[4]
Campbell P, 1996, Proc Inst Mech Eng H, V210, P167, DOI 10.1243/PIME_PROC_1996_210_409_02
[5]
ENDO MM, 2001, THESIS U LEEDS
[6]
Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro [J].
Green, TR ;
Fisher, J ;
Stone, M ;
Wroblewski, BM ;
Ingham, E .
BIOMATERIALS, 1998, 19 (24) :2297-2302
[7]
Hailey J L, 1996, Proc Inst Mech Eng H, V210, P3, DOI 10.1243/PIME_PROC_1996_210_385_02
[8]
HAILEY JL, 1996, P 5 WORLD BIOM C, P550
[9]
Biological reactions to wear debris in total joint replacement [J].
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) :21-37
[10]
Number of polyethylene particles and osteolysis in total joint replacements - A quantitative study using a tissue-digestion method [J].
Kobayashi, A ;
Freeman, MAR ;
Bonfield, W ;
Kadoya, Y ;
Yamac, T ;
AlSaffar, N ;
Scott, G ;
Revell, PA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05) :844-848