Photogrammetric calibration and accuracy evaluation of a cross-pattern stripe projector

被引:27
作者
Brenner, C [1 ]
Böhm, J [1 ]
Gühring, J [1 ]
机构
[1] Univ Stuttgart, Inst Photogrammetry, D-70049 Stuttgart, Germany
来源
VIDEOMETRICS VI | 1998年 / 3641卷
关键词
calibration; coded light system; bundle adjustment; range sensor; 3D surface measurement;
D O I
10.1117/12.333780
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Presently there is a growing demand for fast and precise 3D computer vision systems for a wide variety of industrial applications like reverse engineering, quality control and industrial gauging. One important aspect of any vision system is the data acquisition. If the principle of triangulation is used the correspondence problem is to be solved. The coded light approach offers a fast way to overcome this problem and to provide dense range data. In order to get high accuracy range images the system needs to be calibrated. In this paper, we compare two calibration techniques: polynomial depth calibration and photogrammetric calibration. We have carried out both methods independently. To obtain results about the accuracy in object space, we measured the surface of a plane-table.
引用
收藏
页码:164 / 172
页数:9
相关论文
共 12 条
[1]  
*ABW, 1997, 9 ABW
[2]  
ALTSCHULER M, 1979, SPIE, V182
[3]  
BERALDIN JA, 1993, P SOC PHOTO-OPT INS, V2067, P21, DOI 10.1117/12.162133
[4]  
*BREUCKM GMBH, 13 BREUCKM GMBH
[5]  
FRASER CS, 1996, CLOSE RANGE PHOTOGRA, pCH12
[6]  
*G TECHN GMBH, 1995, PICTRAN B VERS 2 2 0
[7]  
GRUN A, 1994, P COMM 5 S CLOS RA 5, V30, P122
[8]  
KLUDAS P, 1995, IAPRS 5W1, V30, P176
[9]  
KLUDAS T, 1995, IAPRS 5W1, V30, P285
[10]  
STAHS TG, 1990, SPIE, V1395, P496