Qualitative evaluation of thermal desorption-programmable temperature vaporization-comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry for the analysis of selected halogenated contaminants

被引:42
作者
Focant, JF [1 ]
Sjödin, A [1 ]
Patterson, DG [1 ]
机构
[1] CDCP, Natl Ctr Environm Hlth, Div Sci Lab, OAT Branch, Atlanta, GA 30341 USA
关键词
thermal desorption; gas chromatography; comprehensive two-dimensional; polychlorinated biphenyls; polybrominated diphenyl ethers; pesticides;
D O I
10.1016/j.chroma.2003.07.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation of 38 toxic and predominant polychlorinated biphenyl (PCB) congeners, I I persistent halogenated pesticides, I brominated biphenyl (BB), and 8 polybrominated diphenyl ethers (PBDEs) has been optimized using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC x GC-TOFMS). A thermal desorption-programmable temperature vaporization (TD-PTV) step was used for the injection. Different column sets were investigated. and a 100% dimethylpolysiloxane (15 m x 0.25 mm W. x 0.25 mum film thickness) narrowbore capillary column coupled to a high temperature (8% phenyl)-polycarborane-siloxane (2 m x 0.10 mm i.d. x 0.10 mum film thickness) microbore column set was selected. Of the 58 compounds investigated, only one pair of PCBs was not resolved. All other analytes were either baseline separated into the chromatographic plane or were virtually separated using the deconvolution capability of the TOFMS. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:143 / 156
页数:14
相关论文
共 42 条
[1]  
Baltussen E, 1997, HRC-J HIGH RES CHROM, V20, P385
[2]   Sorptive sample preparation - a review [J].
Baltussen, E ;
Cramers, CA ;
Sandra, PJF .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (1-2) :3-22
[3]  
BARR JR, 1997, ORGANOHALOGEN COMPD, V31, P276
[4]   Simple, non-moving modulation interface for comprehensive two-dimensional gas chromatography [J].
Beens, J ;
Adahchour, M ;
Vreuls, RJJ ;
van Altena, K ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) :127-132
[5]   Stir bar sorptive extraction-thermal desorption-capillary gas chromatography-mass spectrometry applied to the analysis of polychlorinated biphenyls in human sperm [J].
Benijts, T ;
Vercammen, J ;
Dams, R ;
Tuan, HP ;
Lambert, W ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2) :137-142
[6]  
BERTSCH W, 1999, J HIGH RES CHROMATOG, V22, P647
[7]  
de Geus HJ, 1998, HRC-J HIGH RES CHROM, V21, P411
[8]  
DEARMAS E, 2002, PITTCON 2000 NEW ORL
[9]   ASSESSMENT OF HAZARDS OF POLYBROMINATED BIPHENYLS [J].
DICARLO, FJ ;
SEIFTER, J ;
DECARLO, VJ .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1978, 23 (APR) :351-365
[10]  
DIMANDJA JM, 1999, ORGANOHALOGEN COMPD, V40, P23