Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual-energy X-ray absorptiometry -: a 3-year follow-up study

被引:146
作者
Venesmaa, PK
Kröger, HPJ
Miettinen, HJA
Jurvelin, JS
Suomalainen, OT
Alhava, EM
机构
[1] Kuopio Univ Hosp, Dept Surg, SF-70210 Kuopio, Finland
[2] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, SF-70210 Kuopio, Finland
关键词
dual-energy X-ray absorptiometry; bone mineral density; total hip arthroplasty; uncemented prosthesis;
D O I
10.1359/jbmr.2001.16.6.1056
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Insertion of a metallic implant into the femur changes bone loading conditions and results in remodeling of femoral bone. To quantify changes in bone mass after uncemented total hip arthroplasty (THA), we monitored femoral bone,vith dual-energy X-ray absorptiometry (DXA), The periprosthetic bone mineral density (BMD) was measured with Lunar DPX densitometry in seven Gruen zones and the total periprosthetic area at scheduled time intervals in 22 patients during a 3-year follow-up. BMD decreased significantly almost in all Gruen zones during the first 3 months, ranging from 3.4% to 14.4% (p < 0.05 to p < 0.001), At the end of the first gear, the most remarkable decrease in BMD was found in the calcar (zone 7; -22.9%). During the second postoperative year, a slight restoration of periprosthetic bone mass was recorded, During the third year, no significant changes in BMD were found, The preoperative BMD was the only factor that was significantly related to the periprosthetic bone loss. Clearly, the early periprosthetic bone loss noticed during the 3 months after THA is caused by mainly limited weight bearing to the operated hip and stress shielding. We suggest that the restoration of bone mass is a sign of successful osteointegration between bone and metallic implant. DXA is a suitable tool to follow the bone response to prosthetization and will increase our knowledge on the behavior of bone after THA.
引用
收藏
页码:1056 / 1061
页数:6
相关论文
共 19 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
[3]
Engh CA., 1990, CLIN ORTHOP RELAT R, V257, P107
[4]
HUISKES R, 1992, CLIN ORTHOP RELAT R, P124
[5]
KANNUS P, 1994, J BONE MINER RES, V9, P423
[6]
DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENT OF BONE-MINERAL DENSITY AROUND POROUS-COATED CEMENTLESS FEMORAL IMPLANTS - METHODS AND PRELIMINARY-RESULTS [J].
KILGUS, DJ ;
SHIMAOKA, EE ;
TIPTON, JS ;
EBERLE, RW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :279-287
[7]
Kiratli BJ, 1996, J ARTHROPLASTY, V11, P184
[8]
DETERMINATION OF BONE-MINERAL DENSITY BY DUAL X-RAY ABSORPTIOMETRY IN PATIENTS WITH UNCEMENTED TOTAL HIP-ARTHROPLASTY [J].
KIRATLI, BJ ;
HEINER, JP ;
MCBEATH, AA ;
WILSON, MA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (06) :836-844
[9]
Kroger H, 1996, J BONE MINER RES, V11, P1526
[10]
Marchetti ME, 1996, J BONE MINER RES, V11, P1033