Cardiac-induced physiologic noise in tissue is a direct observation of cardiac-induced fluctuations

被引:59
作者
Bhattacharyya, PK [1 ]
Lowe, MJ
机构
[1] Indiana Univ, Sch Med, Dept Radiol, Indianapolis, IN 46202 USA
[2] Cleveland Clin Fdn, Div Radiol, Cleveland, OH 44195 USA
关键词
physiologic fluctuations; steady state free precession; aliasing; fMRI; BOLD;
D O I
10.1016/j.mri.2003.08.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent studies have shown that in certain cases, cardiac and respiratory rate fluctuations in BOLD-weighted MR1 time courses may be an artifact unique to rapid sampled acquisitions and may not be present in longer repetition-time acquisitions. The implication of this is that, in these cases, cardiac and respiratory rate fluctuations are not aliased into data that undersample these effects and do not affect the resulting time course measurements. In this study, we show that these cases are specific to regions of large cerebrospinal fluid content and are not generally true for gray matter regions of the brain. We demonstrate that in many brain regions of interest, these fluctuations are directly observed as BOLD fluctuations and thus will affect measurements that undersample these effects. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 16 条
[1]   FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI [J].
BISWAL, B ;
YETKIN, FZ ;
HAUGHTON, VM ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :537-541
[2]   Reduction of physiological fluctuations in fMRI using digital filters [J].
Biswal, B ;
DeYoe, EA ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :107-113
[3]   Localization of cardiac-induced signal change in fMRI [J].
Dagli, MS ;
Ingeholm, JE ;
Haxby, JV .
NEUROIMAGE, 1999, 9 (04) :407-415
[4]  
Jezzard P., 1993, P SMRM 12 ANN M NEW, P1392
[5]   Reducing cardiac noise in BOLD-weighted voxel time courses in an fMRI dataset by increasing TR and/or applying a crusher gradient in an EPI acquisition pulse [J].
Li, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :629-629
[6]  
Li SJ, 2000, MAGNET RESON MED, V43, P45, DOI 10.1002/(SICI)1522-2594(200001)43:1<45::AID-MRM6>3.0.CO
[7]  
2-0
[8]   Functional connectivity in single and multislice echoplanar imaging using resting-state fluctuations [J].
Lowe, MJ ;
Mock, BJ ;
Sorenson, JA .
NEUROIMAGE, 1998, 7 (02) :119-132
[9]  
LOWE MJ, 1999, NEUROIMAGE, V9, pS230
[10]  
Lund T.E., 2001, Proc Intl Soc Mag Reson Med, V9, P22