Hydrogen bond acidic polymers for surface acoustic wave vapor sensors and arrays

被引:85
作者
Grate, JW
Patrash, SJ
Kaganove, SN
Wise, BM
机构
[1] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
[2] Eigenvector Res Inc, Manson, WA 98831 USA
关键词
D O I
10.1021/ac9810011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four hydrogen bond acidic polymers are examined as sorbent layers on acoustic wave devices for the detection of basic vapors. A polysiloxane polymer with pendant hexafluoro-2-propanol groups and polymers with hexafluorobisphenol groups linked by oligosiloxane spacers yield sensors that respond more rapidly and with greater sensitivity than fluoropolyol, a material used in previous SAW sensor studies. Sensors coated with the new materials all reach 90% of full response within 6 s of the first indication of a response. Unsupervised learning techniques applied to pattern-normalized sensor array data were used to examine the spread of vapor data in feature space when the array does or does not contain hydrogen bond acidic polymers. The radial distance in degrees between pattern-normalized data points was utilized to obtain quantifiable distances that could be compared as the number and chemical diversity of the polymers in the array were varied. The hydrogen bond acidic polymers significantly increase the distances between basic vapors and nonpolar vapors when included in the array.
引用
收藏
页码:1033 / 1040
页数:8
相关论文
共 40 条
[1]   HYDROGEN-BONDING .29. CHARACTERIZATION OF 14 SORBENT COATINGS FOR CHEMICAL MICROSENSORS USING A NEW SOLVATION EQUATION [J].
ABRAHAM, MH ;
ANDONIANHAFTVAN, J ;
DU, CM ;
DIART, V ;
WHITING, GS ;
GRATE, JW ;
MCGILL, RA .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1995, (02) :369-378
[2]   SENSITIVITY AND SELECTIVITY OF SURFACE ACOUSTIC-WAVE SENSORS FOR ORGANIC-SOLVENT VAPOR DETECTION [J].
AMATI, D ;
ARN, D ;
BLOM, N ;
EHRAT, M ;
SAUNOIS, J ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :587-591
[3]  
[Anonymous], ANAL CHEM
[4]   VERSATILE MICROCONTROLLED GAS SENSOR ARRAY SYSTEM USING THE QUARTZ MICROBALANCE PRINCIPLE AND PATTERN-RECOGNITION METHODS [J].
AUGE, J ;
HAUPTMANN, P ;
HARTMANN, J ;
ROSLER, S ;
LUCKLUM, R .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 26 (1-3) :181-186
[5]   CORRELATION OF SURFACE ACOUSTIC-WAVE DEVICE COATING RESPONSES WITH SOLUBILITY PROPERTIES AND CHEMICAL-STRUCTURE USING PATTERN-RECOGNITION [J].
BALLANTINE, DS ;
ROSE, SL ;
GRATE, JW ;
WOHLTJEN, H .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :3058-3066
[6]   POLYMER SORBENTS FOR PHOSPHORUS ESTERS .2. HYDROGEN-BOND DRIVEN SORPTION IN FLUORO-CARBINOL SUBSTITUTED POLYSTYRENE [J].
BARLOW, JW ;
CASSIDY, PE ;
LLOYD, DR ;
YOU, CJ ;
CHANG, Y ;
WONG, PC ;
NORIYAN, J .
POLYMER ENGINEERING AND SCIENCE, 1987, 27 (10) :703-715
[7]   SELECTION OF ADSORBATES FOR CHEMICAL SENSOR ARRAYS BY PATTERN-RECOGNITION [J].
CAREY, WP ;
BEEBE, KR ;
KOWALSKI, BR ;
ILLMAN, DL ;
HIRSCHFELD, T .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :149-153
[8]   MULTICOMPONENT ANALYSIS USING AN ARRAY OF PIEZOELECTRIC CRYSTAL SENSORS [J].
CAREY, WP ;
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (11) :1529-1534
[9]   CHEMICAL PIEZOELECTRIC SENSOR AND SENSOR ARRAY CHARACTERIZATION [J].
CAREY, WP ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :3077-3084
[10]   ODOR-SENSING SYSTEM USING A QUARTZ-RESONATOR SENSOR ARRAY AND NEURAL-NETWORK PATTERN-RECOGNITION [J].
EMA, K ;
YOKOYAMA, M ;
NAKAMOTO, T ;
MORIIZUMI, T .
SENSORS AND ACTUATORS, 1989, 18 (3-4) :291-296