Low-dose, dynamic, expiratory thin-section CT of the lungs using a spiral CT scanner

被引:22
作者
Gotway, MB [1 ]
Lee, ES [1 ]
Reddy, GP [1 ]
Golden, JA [1 ]
Webb, WR [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
thin section CT; bronchiolitis obliterans; expiratory; lung attenuation; transplant;
D O I
10.1097/00005382-200007000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Seventeen patients with lung transplants were evaluated with inspiratory, postexpiratory, and low-dose, dynamic expiratory thin-section computed tomography (CT). Region of interest measurements were performed on inspiration and expiration images with both techniques, and mean lung attenuation changes between inspiration and expiration images were calculated and compared. Dynamic expiratory thin-section CT resulted in a significantly greater increase in lung attenuation than postexpiratory thin-section CT. Dynamic expiratory thin-section CT may prove useful in the evaluation of patients with lung diseases characterized by air flow obstruction with little increase in patient radiation dose.
引用
收藏
页码:168 / 172
页数:5
相关论文
共 10 条
[1]   Air trapping on expiratory high-resolution CT scans in the absence of inspiratory scan abnormalities: Correlation with pulmonary function tests and differential diagnosis [J].
Arakawa, H ;
Webb, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1349-1353
[2]   Inhomogeneous lung attenuation at thin-section CT: Diagnostic value of expiratory scans [J].
Arakawa, H ;
Webb, WR ;
McCowin, M ;
Katsou, G ;
Lee, KN ;
Seitz, RF .
RADIOLOGY, 1998, 206 (01) :89-94
[3]   SPIROMETRICALLY CONTROLLED QUANTITATIVE CT FOR ASSESSING DIFFUSE PARENCHYMAL LUNG-DISEASE [J].
BEINERT, T ;
BEHR, J ;
MEHNERT, F ;
KOHZ, P ;
SEEMANN, M ;
RIENMULLER, R ;
REISER, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (06) :924-931
[4]   Air trapping in children: Evaluation with dynamic lung densitometry with spiral CT [J].
Johnson, JL ;
Kramer, SS ;
Mahboubi, S .
RADIOLOGY, 1998, 206 (01) :95-101
[5]   MEASUREMENT OF PULMONARY PARENCHYMAL ATTENUATION - USE OF SPIROMETRIC GATING WITH QUANTITATIVE CT [J].
KALENDER, WA ;
RIENMULLER, R ;
SEISSLER, W ;
BEHR, J ;
WELKE, M ;
FICHTE, H .
RADIOLOGY, 1990, 175 (01) :265-268
[6]  
MULLER NL, 1995, RADIOLOGY, V196, P3
[7]   LOW-DOSE CT OF THE LUNGS - PRELIMINARY-OBSERVATIONS [J].
NAIDICH, DP ;
MARSHALL, CH ;
GRIBBIN, C ;
ARAMS, RS ;
MCCAULEY, DI .
RADIOLOGY, 1990, 175 (03) :729-731
[8]  
Stern E J, 1993, J Thorac Imaging, V8, P273, DOI 10.1097/00005382-199323000-00003
[9]   DYNAMIC QUANTITATIVE COMPUTED-TOMOGRAPHY - A PREDICTOR OF PULMONARY-FUNCTION IN OBSTRUCTIVE LUNG-DISEASES [J].
STERN, EJ ;
WEBB, WR ;
GAMSU, G .
INVESTIGATIVE RADIOLOGY, 1994, 29 (05) :564-569
[10]   DYNAMIC PULMONARY CT - FINDINGS IN HEALTHY ADULT MEN [J].
WEBB, WR ;
STERN, EJ ;
KANTH, N ;
GAMSU, G .
RADIOLOGY, 1993, 186 (01) :117-124