Optimizing the energy and exergy of building integrated photovoltaic thermal (BIPVT) systems under cold climatic conditions

被引:219
作者
Agrawal, Basant [1 ]
Tiwari, G. N. [1 ]
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
Roofing system; Air heating system; Building integrated photovoltaic thermal (BIPVT); Photovoltaic (PV); Solar energy; Renewable energy; PERFORMANCE EVALUATION; SOLAR-COLLECTOR;
D O I
10.1016/j.apenergy.2009.06.011
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Building integrated photovoltaic thermal (BIPVT) system has the potential to become a major source of renewable energy in the urban environment. In this paper, the system has been used as the roof top of a building to generate higher electrical energy per unit area and to produce necessary thermal energy required for space heating. One-dimensional transient: model has been developed using basic heat transfer equations. On the basis of this model, an analysis has been carried in order to select an appropriate BIPVT system suitable for the cold climatic conditions of India. The PV performances, net energy gain and exergy of the building are determined. The results show that for a constant mass flow rate of air the system connected in series gives a better performance whereas for a constant velocity of air flow the system connected in parallel gives a better performance. The BIPVT system, fitted on the rooftop in an effective area of 65 m(2), is capable of annually producing the net electrical and thermal exergies of 16,209 kW h and 1531 kW h, respectively, at an overall thermal efficiency of 53.7%. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:417 / 426
页数:10
相关论文
共 20 条
[1]  
AGRAWAL B, 2009, INT J GREEN ENERGY
[2]   Performance of a building integrated photovoltaic/thermal (BIPVT) solar collector [J].
Anderson, T. N. ;
Duke, M. ;
Morrison, G. L. ;
Carson, J. K. .
SOLAR ENERGY, 2009, 83 (04) :445-455
[3]  
[Anonymous], DEV ENV DURABILITY P
[4]   Research of BIPV optimal tilted angle, use of latitude concept for south orientated plans [J].
Cheng, C. L. ;
Jimenez, Charles S. Sanchez ;
Lee, Meng-Chieh .
RENEWABLE ENERGY, 2009, 34 (06) :1644-1650
[5]   Annual performance of building-integrated photovoltaic/water-heating system for warm climate application [J].
Chow, T. T. ;
Chan, A. L. S. ;
Fong, K. F. ;
Lin, Z. ;
He, W. ;
Ji, I. .
APPLIED ENERGY, 2009, 86 (05) :689-696
[6]  
*DEP AT EN, 10 DEP AT EN
[7]   SIMPLIFIED METHOD FOR PREDICTING PHOTO-VOLTAIC ARRAY OUTPUT [J].
EVANS, DL .
SOLAR ENERGY, 1981, 27 (06) :555-560
[8]   Annual exergy evaluation on photovoltaic-thermal hybrid collector [J].
Fujisawa, T ;
Tani, T .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 1997, 47 (1-4) :135-148
[9]   Study on thermal performance of semi-transparent building-integrated photovoltaic glazings [J].
Fung, Tady Y. Y. ;
Yang, H. .
ENERGY AND BUILDINGS, 2008, 40 (03) :341-350
[10]   Hybrid photovoltaic and thermal solar-collector designed for natural circulation of water [J].
He, W ;
Chow, TT ;
Ji, J ;
Lu, JP ;
Pei, G ;
Chan, LS .
APPLIED ENERGY, 2006, 83 (03) :199-210