Hamstring graft tibial fixation: biomechanical properties of different linkage systems

被引:9
作者
Gobbi, A [1 ]
Mahajan, S [1 ]
Tuy, B [1 ]
Panuncialman, I [1 ]
机构
[1] Orthoped Arthroscop Surg Int, I-20133 Milan, Italy
关键词
anterior cruciate ligament reconstruction Hamstring tendon grafts; Orthotape; Mersilene;
D O I
10.1007/s00167-002-0316-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This biomechanical study analyzed the mechanical properties of different linkage systems commonly used in hamstring tendon ACL reconstruction. Two kinds of tapes, 5-mm braided polyester (Mersilene) and 3-mm. woven polyester (Orthotape), were connected to a particular staple in bovine bone sections in single- and double-loop constructs with five replicates of each. These constructs underwent straight pull tensile tests, residual tensile tests, and fatigue tests at a loading regime of 540,000 cycles at 25 Hz frequency, using an Instron tensile test machine. Protrusion heights of the constructs were measured. The double-loop Mersilene-Fastlok construct was weaker than either single-loop or double-loop Orthotape-Fastlok construct. The mean failure strength of double-loop Orthotape-Fastlok was 93% higher and its mean stiffness was 40% greater at failure than that of Mersilene-Fastlok. At a 150-N load Mersilene-Fastlok was stiffer, while at 300 N Orthotape-Fastlok was stiffer. The thickness of Orthotape-Fastlok resulted in 1 min more device protrusion. In hamstring tendon ACL reconstructions with indirect fixation we advocate the use of woven polyester (Orthotape) with Fastlok as a linkage material over braided polyester (Mersilene) with Fastlok because of its superior strength and stiffness.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 16 条
[1]
Graft fixation in cruciate ligament reconstruction [J].
Brand, J ;
Weiler, A ;
Caborn, DNM ;
Brown, CH ;
Johnson, DL .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05) :761-774
[2]
BROWN CH, 1998, TECH ORTHOP, V13, P281
[3]
CORBMAN BP, 1983, TEXTILES FIBERS FABR
[4]
Current concepts review - The science of reconstruction of the anterior cruciate ligament [J].
Frank, CB ;
Jackson, DW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (10) :1556-1576
[5]
Current trends in anterior cruciate ligament reconstruction Part II. Operative procedures and clinical correlations [J].
Fu, FH ;
Bennett, CH ;
Ma, CB ;
Menetrey, J ;
Lattermann, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (01) :124-130
[6]
Hamstring graft motion in the femoral bone tunnel when using titanium button/polyester tape fixation [J].
Höher, J ;
Livesay, GA ;
Ma, CB ;
Withrow, JD ;
Fu, FH ;
Woo, SLY .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (04) :215-219
[7]
Bone tunnel enlargement after anterior cruciate ligament reconstruction: Fact or fiction? [J].
Höher J. ;
Möller H.D. ;
Fu F.H. .
Knee Surgery, Sports Traumatology, Arthroscopy, 1998, 6 (4) :231-240
[8]
The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system [J].
Ishibashi, Y ;
Rudy, TW ;
Livesay, GA ;
Stone, JD ;
Fu, FH ;
Woo, SLY .
ARTHROSCOPY, 1997, 13 (02) :177-182
[9]
A BIOMECHANICAL COMPARISON OF DIFFERENT SURGICAL TECHNIQUES OF GRAFT FIXATION IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
KUROSAKA, M ;
YOSHIYA, S ;
ANDRISH, JT .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1987, 15 (03) :225-229
[10]
LATTERMAN C, 1998, HAMSTRING VERSUS PAT, P160