Quantitative evaluation of 2 x 2 arrays of Lucite cone applicators in flat layered phantoms using Gaussian-beam-predicted and thermographically measured SAR distributions

被引:13
作者
Rietveld, PJM
Lumori, MLD
van der Zee, J
van Rhoon, GC
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Dept Radiat Oncol, Subdiv Hyperthermia, Rotterdam, Netherlands
[2] Free Univ Brussels, Vesalius Coll, B-1050 Brussels, Belgium
[3] Free Univ Brussels, Dept Elect Engn, B-1050 Brussels, Belgium
关键词
D O I
10.1088/0031-9155/43/8/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
SAR distributions from four different E-field-orientated 2 x 2 arrays of incoherently driven Lucite cone applicators (LCAs) were investigated. The LCAs operated at 433 MHz with an aperture of 10.5 cm x 10.5 cm each. Two techniques were used to obtain SAR distributions in Bat layered phantoms: Gaussian beam (GB) predictions and thermographical (TG) imaging. The GB predictions showed that the effective field size of the different array configurations varied by up to 3%. The TG-measured SAR distribution showed significant deviations from the GB-predicted SAR distributions (maximum 34.6%). The difference between GB-predicted and TG-measured SAR levels (averaged per 10% GB-predicted SAR intervals) equalled less than 11.3% for the parallel E-field orientated array and respectively 15.1% for the clockwise-orientated array. When antennae in the clockwise-orientated array were more widely spread (array aperture 23 cm x 23 cm) in order to diminish their mutual interactions, these differences decreased to 12.4%. However, the overall difference within the 50% SAR or higher range decreased from 14% to 9%. The results lead us to conclude that LCAs can be used clinically and their antenna interactions are not considered to be a problem under clinical conditions.
引用
收藏
页码:2207 / 2220
页数:14
相关论文
共 18 条
[1]  
Andersen J. B., 1987, PHYSICS TECHNOLOGY H, P159
[2]   An attempt at quantitative specification of SAR distribution homogeneity [J].
Gelvich, EA ;
Mazokhin, VN ;
Troshin, II .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1996, 12 (03) :431-436
[4]   QUALITY ASSURANCE GUIDELINES FOR ESHO PROTOCOLS [J].
HAND, JW ;
LAGENDIJK, JJW ;
ANDERSEN, JB ;
BOLOMEY, JC .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1989, 5 (04) :421-428
[5]  
HAND JW, 1992, HYPERTHERMIC ONCOLOG
[6]  
IBBOTT GS, 1989, 26 AM ASS PHYS MED
[7]   NONIONIZING ELECTROMAGNETIC WAVE EFFECTS IN BIOLOGICAL-MATERIALS AND SYSTEMS [J].
JOHNSON, CC ;
GUY, AW .
PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1972, 60 (06) :692-&
[8]   GAUSSIAN-BEAM REPRESENTATION OF APERTURE FIELDS IN LAYERED, LOSSY MEDIA - SIMULATION AND EXPERIMENT [J].
LUMORI, MLD ;
ANDERSEN, JB ;
GOPAL, MK ;
CETAS, TC .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1990, 38 (11) :1623-1630
[9]   USE OF GAUSSIAN-BEAM MODEL IN PREDICTING SAR DISTRIBUTIONS FROM CURRENT SHEET APPLICATORS [J].
LUMORI, MLD ;
HAND, JW ;
GOPAL, MK ;
CETAS, TC .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) :387-397
[10]  
LUMORI MLD, 1988, THESIS U ARIZONA