An improved assay for the N-acetyl-D-glucosamine reducing ends of polysaccharides in the presence of proteins

被引:38
作者
Asteriou, T [1 ]
Deschrevel, B
Delpech, B
Bertrand, P
Bultelle, F
Merai, C
Vincent, JC
机构
[1] Univ Rouen, IFR Syst Integres, CNRS 61, F-76821 Mt St Aignan, France
[2] Univ Rouen, CNRS,UMR 6522, Lab Polymeres Biopolymeres Membranes, F-76821 Mt St Aignan, France
[3] Ctr Henri Becquerel, Oncol Mol Lab, F-76038 Rouen, France
关键词
hyaluronan assay; hyaluronidase kinetics; N-acetyl-glucosamine reducing end assay; Reissig assay; hyaluronan; hyaluronidase; presence of proteins; colorimetry; turbidity; polysaccharide-protein complexes;
D O I
10.1006/abio.2001.5068
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hyaluronan concentration and hyaluronidase activity can be assayed by using different techniques including turbidimetry, viscosimetry, ELISA, chromatography, and colorimetry, The most popular colorimetric method is that of J. Reissig et al. (1955, J. Biol. Chem. 217, 959-966), in which the color results from a reaction between the Ehrlich's reagent (DMAB) and the N-acetyl-D-glucosamine reducing end of each hyaluronan chain. Nevertheless, there are problems with this method when proteins are present in the medium. Here we propose a new interpretation of the Reissig signal for estimating such reducing ends in media containing enzymes or other proteins. This interpretation is based on the fact that the absorbance obtained by using the Reissig method results from two factors: a turbidity due to the formation of polysaccharide-protein complexes and a color resulting fi-om the action of DMAB on the reducing end of the polysaccharide chains. The turbidity at 585 nm, the wavelength at which the color intensity is maximal, may be estimated by curve fitting the spectrum between 450 and 650 nm. Subtracting the turbidity from the absorbance gives the colorimetric intensity which represents the concentration of polysaccharide chains. Moreover, the turbidity may give additional information about the existence of polysaccharide-protein complexes and their nature. (C) 2001 Academic Press.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 29 条
[1]   SENSITIVE METHOD FOR ASSAY OF HYALURONIDASE ACTIVITY [J].
BENCHETRIT, LC ;
PAHUJA, SL ;
GRAY, ED ;
EDSTROM, RD .
ANALYTICAL BIOCHEMISTRY, 1977, 79 (1-2) :431-437
[2]   A REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR BOVINE TESTICULAR HYALURONIDASE DIGESTS USING POSTCOLUMN DERIVATIZATION WITH 2-CYANOACETAMIDE AND ULTRAVIOLET DETECTION [J].
CRAMER, JA ;
BAILEY, LC .
ANALYTICAL BIOCHEMISTRY, 1991, 196 (01) :183-191
[3]   AN INDIRECT ENZYMOIMMUNOLOGICAL ASSAY FOR HYALURONIDASE [J].
DELPECH, B ;
BERTRAND, P ;
CHAUZY, C .
JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 104 (1-2) :223-229
[4]   A COMPARISON OF SERUM AND TESTICULAR HYALURONIDASE [J].
DESALEGU.M ;
PLONSKA, H ;
PIGMAN, W .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1967, 121 (03) :548-&
[5]  
DORFMAN A, 1948, J BIOL CHEM, V172, P367
[6]  
DORFMAN A, 1948, J BIOL CHEM, V172, P377
[7]   A colorimetric method for the determination of glucosamine and chondrosamine. [J].
Elson, LA ;
Morgan, WTJ .
BIOCHEMICAL JOURNAL, 1933, 27 :1824-1828
[8]   A RECOMMENDED PROCEDURE FOR THE ESTIMATION OF BOVINE TESTICULAR HYALURONIDASE IN THE PRESENCE OF HUMAN-SERUM [J].
GACESA, P ;
SAVITSKY, MJ ;
DODGSON, KS ;
OLAVESEN, AH .
ANALYTICAL BIOCHEMISTRY, 1981, 118 (01) :76-84
[9]   Effect of Ionic Strength and Serum on the Activity Profile of Bovine Testicular Hyaluronidase [J].
Gacesa, Peter ;
Savitsky, Marc J. ;
Dodgson, Kenneth S. ;
Olavesen, Anthony H. .
BIOCHEMICAL SOCIETY TRANSACTIONS, 1979, 7 :1287-1289
[10]   EFFECT OF IONIC-STRENGTH AND PH ON PROPERTIES OF PURIFIED BOVINE TESTICULAR HYALURONIDASE [J].
GORHAM, SD ;
OLAVESEN, AH ;
DODGSON, KS .
CONNECTIVE TISSUE RESEARCH, 1975, 3 (01) :17-25