Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions

被引:280
作者
Achenbach, S [1 ]
Moshage, W [1 ]
Ropers, D [1 ]
Nossen, J [1 ]
Daniel, WG [1 ]
机构
[1] Univ Erlangen Nurnberg, Med Klin & Poliklin 2, Dept Internal Med 2, D-91054 Erlangen, Germany
关键词
D O I
10.1056/NEJM199812313392702
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Reliable noninvasive assessment of coronary-artery stenoses and occlusions would constitute an advantage in the care of patients with known or suspected coronary artery disease. We investigated the accuracy of contrast-enhanced electron-beam computed tomography (CT) for the detection of high-grade coronary-artery stenoses and occlusions. Methods Electron-beam CT was performed in 125 patients. After intravenous injection of a contrast agent, 40 cross-sectional images of the heart were acquired during inspiration, triggered by the electrocardiogram in diastole. Three-dimensional reconstructions of the heart and coronary arteries were rendered to facilitate evaluation of the images. The proximal and middle segments of the major coronary arteries were evaluated for the presence or absence of high-grade stenoses and occlusions, The results were compared with those of invasive coronary angiography in a blinded fashion. Results Because of technical problems that impaired the quality of the images, 124 (25 percent) of the 500 coronary arteries studied (left main, left anterior descending, left circumflex, and right coronary) in a total of 125 patients were excluded from evaluation. No vessels could be evaluated in 19 patients (15 percent), and another 28 patients (22 percent) had one, two, or three vessels that could not be evaluated. In the remaining coronary arteries with adequate image quality, electron-beam CT permitted visualization of 69 of 75 high-grade stenoses and occlusions (sensitivity, 92 percent), whereas in 282 of 301 arteries, the absence of high-grade stenoses and occlusions was correctly detected (specificity, 94 percent). Conclusions When image quality is adequate, electron-beam CT may be useful to detect or rule out high-grade coronary-artery stenoses and occlusions. (N Engl J Med 1998;339:1964-71.) (C) 1998, Massachusetts Medical Society.
引用
收藏
页码:1964 / 1971
页数:8
相关论文
共 43 条
[1]   Detection of high-grade restenosis after PTCA using contrast-enhanced electron beam CT [J].
Achenbach, S ;
Moshage, W ;
Bachmann, K .
CIRCULATION, 1997, 96 (09) :2785-2788
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]  
*AM HEART ASS, 1993, 1993 HEART STROK FAC, P8
[4]  
*AM HEART ASS COMM, 1975, CIRCULATION, V51, P5
[5]   Predictive value of electron beam computed tomography of the coronary arteries - 19-month follow-up of 1173 asymptomatic subjects [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
LledoPerez, A ;
Sherman, S ;
Lerner, C ;
Guerci, AD .
CIRCULATION, 1996, 93 (11) :1951-1953
[6]   PROPOSED DYNAMIC CARDIAC 3-D DENSITOMETER FOR EARLY DETECTION AND EVALUATION OF HEART-DISEASE [J].
BOYD, DP ;
GOULD, RG ;
QUINN, JR ;
SPARKS, R ;
STANLEY, JH ;
HERRMANNSFELDT, WB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2724-2726
[7]   CORONARY-ARTERY CALCIFICATION DETECTED WITH ULTRAFAST CT AS AN INDICATION OF CORONARY-ARTERY DISEASE - WORK IN PROGRESS [J].
BREEN, JF ;
SHEEDY, PF ;
SCHWARTZ, RS ;
STANSON, AW ;
KAUFMANN, RB ;
MOLL, PP ;
RUMBERGER, JA .
RADIOLOGY, 1992, 185 (02) :435-439
[8]  
Budoff M. J., 1997, Journal of the American College of Cardiology, V29, p393A
[9]   Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: A multicenter study [J].
Budoff, MJ ;
Georgiou, D ;
Brody, A ;
Agatston, AS ;
Kennedy, J ;
Wolfkiel, C ;
Stanford, W ;
Shields, P ;
Lewis, RJ ;
Janowitz, WR ;
Rich, S ;
Brundage, BH .
CIRCULATION, 1996, 93 (05) :898-904
[10]   Improved Doppler detection of proximal left anterior descending coronary artery stenosis after intravenous injection of a lung-crossing contrast agent: A transesophageal Doppler echocardiographic study [J].
Caiati, C ;
Aragona, P ;
Iliceto, S ;
Rizzon, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) :1413-1421