Analysis of soil and dust samples for polychlorinated biphenyls by enzyme-linked immunosorbent assay (ELISA)

被引:27
作者
Chuang, JC
Miller, LS
Davis, DB
Peven, CS
Johnson, JC
Van Emon, JM [1 ]
机构
[1] US EPA, Natl Exposure Res Lab, Las Vegas, NV 89193 USA
[2] Battelle Mem Inst, Columbus, OH 43201 USA
关键词
ELISA; GC/ECD; PCB; aroclor; house dust; soil;
D O I
10.1016/S0003-2670(98)00439-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An inhibition enzyme-linked immunosorbent assay (ELISA) was used to determine polychlorinated biphenyls (PCBs) in house dust and soil. Soil and house dust samples were analyzed for PCB by both gas chromatography/electron capture detection (GC/ECD) and ELISA methods. A correlation coefficient of 0.91 was obtained for the 41 soil samples. The correlation between the GC/ECD and the ELISA methods for the 10 house dust samples was not as good as that for the soil samples. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 6 条
[1]  
*ASTM, 1994, ANN BOOK ASTM STAND, P570
[2]  
CHUANG JC, 1995, 822073 US EPA CR
[3]   Quantitative enzyme-linked immunosorbent assay for determination of polychlorinated biphenyls in environmental soil and sediment samples [J].
Johnson, JC ;
VanEmon, JM .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :162-169
[4]  
JOHNSON JC, 1994, EPA600R94112, P9
[5]  
*US EPA, 1990, 3540A US EPA OFF SOL
[6]  
*US EPA, 1990, 8081 US EPA OFF SOL