Assessment of the haemodynamic response to exercise by means of electrical impedance cardiography: Method, validation and clinical applications

被引:17
作者
Bogaard, HJ [1 ]
Woltjer, HH [1 ]
Postmus, PE [1 ]
deVries, PMJM [1 ]
机构
[1] VRIJE UNIV AMSTERDAM, ACAD HOSP, DEPT PULM MED, NL-1007 MB AMSTERDAM, NETHERLANDS
关键词
exercise; cardiac output; stroke volume; impedance cardiography; validation;
D O I
10.1088/0967-3334/18/2/001
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Over the past three decades, the technique of electrical impedance cardiography (EIC) has developed into a valid and reliable instrument for the assessment of stroke volume. Recent developments have made EIC suitable for routine use during exercise testing, too. However, standardization of electrode positioning, stroke volume calculation, and data processing is lacking. In our opinion the most reliable options are, respectively, a modified semicircular electrode array, the Kubicek equation including a haematocrit-based resistivity value, and computerized signal averaging. Although EIC derived stroke volume calculation is based on several debated assumptions, numerous validation studies have shown good accuracy and reproducibility, also during exercise. Addition of EIC measurements during standard clinical exercise resting might be of benefit in occupational medicine, cardiology and pulmonary medicine. Although in the latter setting no validation studies have been performed, major methodological problems are not expected.
引用
收藏
页码:95 / 105
页数:11
相关论文
共 53 条
[1]
A NOMOGRAM FOR CALCULATION OF AEROBIC CAPACITY (PHYSICAL FITNESS) FROM PULSE RATE DURING SUBMAXIMAL WORK [J].
ASTRAND, PO ;
RYHMING, I .
JOURNAL OF APPLIED PHYSIOLOGY, 1954, 7 (02) :218-221
[2]
ASTRAND PO, 1986, TXB WORK PHYSL PHYSL, pCH8
[3]
ASTRAND PO, 1986, TXB WORK PHYSL PHYSL, pCH4
[4]
CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[5]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]
RESPIRATORY FACTORS LIMITING EXERCISE [J].
BYE, PTP ;
FARKAS, GA ;
ROUSSOS, C .
ANNUAL REVIEW OF PHYSIOLOGY, 1983, 45 :439-451
[7]
USING THE LUNGS TO MEASURE CARDIAC-OUTPUT [J].
CRAPO, RO ;
MORRIS, AH .
CHEST, 1987, 92 (01) :3-4
[8]
EXERCISE-INDUCED ARTERIAL HYPOXEMIA IN HEALTHY-HUMAN SUBJECTS AT SEA-LEVEL [J].
DEMPSEY, JA ;
HANSON, PG ;
HENDERSON, KS .
JOURNAL OF PHYSIOLOGY-LONDON, 1984, 355 (OCT) :161-175
[9]
MEASUREMENT OF CARDIAC-OUTPUT BY ELECTRICAL IMPEDANCE AT REST AND DURING EXERCISE [J].
DENNISTON, JC ;
MAHER, JT ;
REEVES, JT ;
CRUZ, JC ;
CYMERMAN, A ;
GROVER, RF .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (01) :91-95
[10]
DOERR BM, 1981, AVIAT SPACE ENVIR MD, V52, P394